ML19309C261

From kanterella
Jump to navigation Jump to search
Forwards QA Program Insp Rept 99900387/79-01 on 791210-14 & Notices of Deviation & Violation
ML19309C261
Person / Time
Issue date: 01/24/1980
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Compas W
GENERAL ATOMICS (FORMERLY GA TECHNOLOGIES, INC./GENER
Shared Package
ML19309C253 List:
References
REF-QA-99900387 NUDOCS 8004080369
Download: ML19309C261 (2)


Text

e we UNITED STATES

(*

  1. "'%q'o NUCLEAR REGULATORY COMMISSION sj L

/

g f

V*

I REGloN IV c

7 d'.

O, 611 RY AN PLAZA oRIVE, SUITE 1000 ARLINGTON, TEX AS 76012

  • i j

<,g a [...'.. /

28 JAN 1980 Docket No. 99900387/79-01 i

General Atomic Company Electronic Systems Division Attn:

Mr. W. J. Compas Director P. O. Box 81608 San Diego, California 92138 Gentlemen:

f This refers to the QA Program inspection conduct. by Mr. W. E. Foster of this office on December 10-14, 1979, of your facility at San Diego, California, associated with the manufacture of radiation monitoring systems and to the discussions of our findings with you and members of your staff at the conclusion of the inspection.

This inspection was made to confirm that, in the areas inspected, your QA Program is being effectively implemented.

The inspection effort is not designed to assure that unique quality requirements imposed by a customer are being implemented; nor to assure that a specific product, component or service provided by you to your customers, is of acceptable quality. As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or services procured from others.

You should therefore not conclude that the NRC's inspection exempts you from inspections by an NRC licensee or his agents nor from taking effective cor-rective action in response to their findings.

Areas examined and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.

During the inspection it was found that the implementation of your QA Program failed to meet certain NRC requirements.

The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.

Please provide us within thirty (30) days of your receipt of this report a written statement containing, (1) a description of steps that have been or will be taken to correct these items, (2) a description of steps that have been or will be taken to prevent recurrence, and (3) the date your corrective actions g(A080)

n General Atomic Company 2

and preventive measures were or will be completed.

Corrective action was taken and preventive measures identified prior to the close of the inspection for Item A. of the Notice of Deviation; consequently, further written j

response to this item is unnecessary.

In accordance with Section 2.790 of the Commission's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter with enclosure and your reply, together with the enclosed inspection report will be placed in the Commission's Public Document Room.

If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure. Any such application must include a full l

statement of the reasons on the basis of which it is claimed that the informa-tion is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, klb b 6+d Uldis Potapovs, Chief Vendor Inspection Branch

Enclosures:

1.

Notice of Violation 2.

Notice of Deviation 3.

Inspection Report No. 99900387/79-01 l

i 4

l L

4

-r