J. T. Collins, Deputy Director U. S. Nuclear Regulatory Commission c/o Three Mile Island Nuclear Station Middletown, Pa.
17057
Dear Sir:
i
\\
Three Mile Island, Nuclear Station, Unit II (TMI-2)
Operating License No. DPR-73 Docket No. 50-320 Reactor Containment Euilding Atmosphere Cleanup In our letter of January 4, 1980 (TLL 002) Metropolitan Edison agreed to forward the results of the reactor building air samples analyzed for Strontium 89 and 90.
The sampling and analyses have been completed and the results are contained in the attachment to this letter.
Sincerely,
/s/ R. F. Wilson R.
F. Wilson Director, TMI-II RFW:.TI: hah Attachment cc: AR2 H. Vollmer.,)
\\
0 0
i 6 \\
l
- .ietrocot an Ec.sen Comcan/ is a !.'emcer ci tre Genera' Put c UNees System 1
P t ac o 4"" %'
P TLL 145 TMI-II REACTOR BUILDING ATMOSPHERE STRONTIUM 89/90 SAMPLE RESULTS SAMPLE NUMBER SAMPLE DATE STRONTIUM 89 STRONTIUM 90 TMI #31210 1/30/80 5.16E-10 uCi/cc 8.71E-10 uCi/cc TMI #31211 1/30/80 7.67E-11 uCi/cc 2.28E-10 uCi/cc TMI #32452 2/13/80 2.14E-ll uCi/cc 1.09E-10 uCi/cc TMI #32453 2/13/80 4.76E-10 uCi/cc 7.13E-10 uCi/cc TMI #31825 2/6/80 8.32E-11 uCi/cc 1.30E-10 uCi/cc f
e 4