ML19309B642

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 9080,Revision 3,for Model HN-600
ML19309B642
Person / Time
Site: 07109080
Issue date: 03/17/1980
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML19309B640 List:
References
NUDOCS 8004070020
Download: ML19309B642 (3)


Text

a a

s 0;

~

Form NRC418 U.S. NUCLEAR REGULATORY COMMISSION I'

CERTIFICATE OF COMPLIANCE gg C R 71 For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.

1.(c) Package identification No.

1.(d) Pages No. 1.te) Total No. Pages 9080 3

' USA /9080/A 1

3-

2. PREAMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Haaerdous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10s and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, ** Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.**

. 2.(c)

This artificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

Hittman Nuclear & Development Hittman Nuclear & Development Corporation application Corporation dated January 12, 1977, as supplemented.

9190 Red Branch Road Columbia, Maryland 21045

- 3.tc) oocket w. 71-9080

4. CONDITIONS
This certificate is conditional upon the fulfilling of the requirements of Subisi 3 of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
5. Description of Packaging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and

References:

a)

Packaging (1) Model No.: HN-600 (2) Description A steel encased, lead shielded cask for low specific activity material. The cask is a right circular cylinder 54-1/2 inches high by 84 inches in diameter. The cask cavity is 40-1/4 inches high by 75-1/2 inches in diameter. The cask side wall consists of a 3/8-inch thick inner steel shell, a 3-inch lead shell, and a 3/4-inch thick outer steel shell. The base is comprised of two steel plates-welded together to form a 5-1/2-inch thick base which is. integrally welded to the inner and outer steel shells of the side wall. A steel flange is welded to the inner and outer shells of the side wall at the top. The 5-1/2-inch thick lid is comprised of two steel plates welded together, which are stepped l

to mate with the steel flange. The cask closure is sealed by a neoprene gasket located between the lid and. steel flange. Positive closure is accomplished by eight ratchet binders. The lid contains a 6-1/2-inch thick centrally located shield plug, comprised of three steel plates stepped and welded. The shield plug is sealed i

by a gasket, and eight 3/4-inch studs and nuts are used to provide j

- positive closure.

~

8004070 O2.0

Fage 2 - Certificate No. 9080 - Revision No. 3 - Docket No. 71-9080 5.

a)

Packaging (cont'd)

(2) Description (cont'd)

Tie-down is accomplished by four tie-down lugs welded to the cask body. There are four cask lifting lugs, three lid lifting lugs, and one shield plug lifting lug. The package gross weight is approximately 48,000 pounds.

(3) Drawings The packaging is fabricated in accordance with Hittman Nuclear

& Development Corporation Drawing Nos. : C001-4-9600, Sheet 1, Rev. C; C001-4-9601, Sheet 1, Rev. B and Sheet 2, Rev' 0;

~

C001-4-9602, Sheet 1, Rev. B and Sheet 2, Rev. 0; C001-4-9603, Sheet 1, Rev. A; and C001-5-9604, Sheet 1, Rev. O.

(b) Contents (1) Type and form of material (1) Solids and solidified waste, meeting the requirements for low specific activity radioactive material as defined in 10 CFR 571.4(g), in secondary containers.

(ii) Activated solid components meeting the requirements for low specific activity radioactive material as defined in 10 CFR 571.4(g).

(2) Maximum quantity of material per package Greater than Type A quantities of radioactive material with the weight of the contents, secondary containers and shoring not exceeding 13,000 pounds.

6.

Shoring shall be placed between secondary containers (or activated components) and the cask cavity to prevent movement during normal conditions of transport.

7.

The lid and shield plug lifting lugs shall not be used for lifting the cask, and shall be covered in transit.

8.

Prior to each shipment, the packaging lid seals shall be inspected. The seals shall be replaced with new seals if inspection shows any defects or every twelve (12) months, whichever occurs first.

9.

The package authorized by this certificate shall'be transported on a motor vehicle, railroad car, aircraft, inland water craft, or hold or deck of a-seagoing vessel assigneo for the sole use of the licensee.

O

Page 3 - Certificate No. 9080 - Revision No. 3 - Docket No. 71-9080

10. The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
11. Expiration date: August 31, 1982.

REFERENCES Hittman Nuclear & Development Corporation application dated January 12, 1977 (includingSARdated1/13/77).

Supplements dated: June 6 and 21, 1977; August 18, 1978; and March 17, 1980.

l FOR THE U.S. NUCLEAR REGULATORY COMISSION M

s-Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:

i O

P

-