Reviews Info Re Control Room Ventilation Sys Tech Specs Transmitted in NRC .Tech Spec Amend to Be Prepared by 750523
ML19309B042
Person / Time
Site: Rancho Seco
Issue date: 04/10/1975
From: Mattimoe J
SACRAMENTO MUNICIPAL UTILITY DISTRICT
To: Purple R
Office of Nuclear Reactor Regulation
References
4121, NUDOCS 8004020517
Download: ML19309B042 (3)


Text

7M*ndDnMEUTIOLFOR PART 50_DOCXET MATERIAL _ _ _ _

(TEllPORARY FORM)

CONTROL NO:

4121 w

FILE:

ROM
SMUD DATE OF DOC DATE REC'D LTR TWX RPT OTHER Sacramento, Calif.

.n J. mttune 4-10-75 4-16-75 u

TO:

ORIG CC OTHER SENT AEC POR

^^

Mr. R. A. Purple

~

l signed ___

SENT LOCAL PDR H

CLASS UNCLASS PROPINFO INPUT NO CYS REC'D DOCKET NO:

0CC l'

DESCRIPTION:

50-312 Ltr re our 2-28-75 ENCLOSURES:

re furnishing info re Tech Specs re. Control Room Ventilation System....

PLANT NAME:

Rancho Seco FOR ACTION /INFORT.1ATION DIE 4-17-75 BUTLER (L)

SCHWENCER (L) ZIEMANN (L)

REG AN (E)

W/ Copics W/ Copies W/ Copies W/ Copies CLARK (L)

STOLZ (L)

DICKER (E)

LEAR (L)

W/ Copies W/ Copiee W/ Copies W/ Copies PARH (L)

VASSAlt KNIGHYON (E)

SPELS W! Cepic:

.//// Ccpi:..

W/ Copis W/ Cupin KNIEL (L)

TURjlE (L)

YOUNGBLOOD (E)

W/ Copies Wg$opics W/ Copies W/ Copies NFGFt h INTERNAL DISTRIBUTION TECH REVIEW DENTON LIC ASST A/T IND.

'NRG POR

~

SCHROEDER GRIMES R. DIGGS (L)

BRAlfEAN WDGC. ROOM P.EOGA MACCARY GAMMILL 4GOSSICK/ STAFF H. GEAPIN (L)

SALTZMAN KNIGHT KASTNER CASE E. GOULBOURNE (L)

MELTZ PAWLICKl BALLARD GIAMBUSSO SHAO SPANGLER J. LEE (L)

PLANS P. KREUTZER (E)

BOYD STELLO MOORE (L)

HOUSTON

_ENVI RO M. MAIG R ET (L)

MCDONALD DEYOUNG (L)

NOVAK MULLEli S. REED (E)

CHAPMAN SKOVHOLT (L)

ROSS DICKER M. SHEPPARD (L)

&G. COUPE M. SERVICE (L) 80UBE (Ltr)

GOLLER (L) (Ltr)

IPPOLITO KNIGHTON P. COL LINS M. SLATER (E)

PETERSON TEDESCO YOUNGBLOOD H. SMITH (L)

HARTFIELD (2)

DENISE LONG MgROJECT LDR EGAN REG OPR S. TEETS (L)

KLECKER LAINAS WE REGION (2)

G. WILLIAMS (E)

EISENHUT BENAROYA A.S d~

V. WILSON (L)

WIGGINTON T.R. WILSON VOLLMER HAR LESS STEELE R. INGRAM (L) h CLQ fN, 2.

EXTERNAL DISTRIBUTION M - LOCAL PDRA9d #A44WT4 0 8N8' 1

0D W-TIC (ASERifATHY') ' (1)(2)(10$ - N ATIONAL LASS -

W-NSIC (BUCHANAN) 1

- PD R. SAN!_..

1 - ASLB

- W. PENNINGTON, Rm E.201 GT 1 - BROOKHAVEN NAT LAB 1 - CONSULTANTS g/Y ACRSTIteomW5ENT TO 4g 1 - Newton Anderson 1 - G. ULRIKSON, C.T:L NEWMARK/BLUME/AGBASIAN 1 - AGMED (RUTH GUSSMAN)

Rm B.127 GT OtPfW ShW.

1 - J. D. RUNKLE'S. Rm E.201 GT

r esuuo SACRAMENTO MUNICIPAL UTILITY DISTRICT C 6201 S Street, Box 15830 Sacramento, California 95813; (916) 452 3211 April 10,1975 Mr. Robert A. Purple, Chief Operating Reactors Branch #1 Division of Reactor Licensing U. S. fluclear Regulatory Commission Washington, D. C.

20555 p(,,,

Dear Mr. Purple:

Rancho Seco Nuclear Generating Station Unit 1 Docket No. 50-312 The information which you sent us in your letter of February 28, 1975 has been reviewed. Our present Technical Speci-fications have the " Control Room Ventilation System" and " Hydrogen Purge System" sections. The Rancho Seco Technical Specificatf.G correspond to these sections as " Emergency Control Room Filteeing System," Section 4.10, " Hydrogen Purge Eystem," Section 4.4.'. and

" Reactor Building Purge Filtering System," Section 4.11.

The technical content of each of the above section:. you sent us has been found to be less restrictive for D0P and halogenated hydrocarbon removal efficiencies. Our present specifications require 99.9% and 99.5% respectively -- well d ove your suggested efficiencies of 99% for both tests.

The maximum pressure drop across the Rancho Seco ! EPA and charcoal absorber banks is to be measured less than three inches of H 0 This is half the permitted pressure differential of six inches allowe$.

in the STS requirements. Many specifications would require redesign of the Rancho Seco ventilation system to meet the surveillailce and testing requirements. We have determined that the importani specifica-tions and calibrations required in your correspondence have already been included in our present Technical Specifications and speci11cally the testing standards of ANSI-N101.1-1972, ANSI-N45-8.3 and Reaulatory Guide 1.52, " Design, Testing, and Maintenance Criteria for Atmospnere Cleanup System Air Filtration and Absorption Units of Light-Water-Cooled Nuclear Power Plants" are being complied with where applicable.

Additionally, the information you sent us is in the Standard l

Technical Specifications terminology and we would not want to revise l

the Technical Specifications to this terminology without a major l

review of the complete document.

If certain sections were written in U 12.l dOO th S

Mr. Robert A. Purple-April 10, 1975 STS terminology and the other sections remain with the original word-ing, we feel we would not improve our Technical Specifications and i

may introduce considerable confusion.

Ilowever, we would propose that the above-mentioned specifications be incorporated into the Rancho Seco Unit One Technical Specifications where applicable, short of redesigning or inodification of the present system and include all j

the Rancho Seco nomenclature.

The revisions will be completed, reviewed and approved by the Audit Committees about mid-May.

You should receive the proposed amendment to the Rancho Seco Technical Specifications prior to May 23, 1975.

Sincerely yours, J

', fmdCCi&L

'J. 'J. Mattimoe Assistant General Manager and Chief Engineer

~