ML19309A768

From kanterella
Jump to navigation Jump to search
Response to Aslab 800303 Memorandum & Order.Recent Info Re Turbine Disc Cracking Will Not Change NRC Estimates of Turbine Missile Risks.Nrc Will Indicate Whether Changes Are Needed Re Testimony.Questions Re Cracking Sent to Licensees
ML19309A768
Person / Time
Site: North Anna  
Issue date: 03/24/1980
From: Swanson D
NRC OFFICE OF THE EXECUTIVE LEGAL DIRECTOR (OELD)
To:
NRC ATOMIC SAFETY & LICENSING APPEAL PANEL (ASLAP)
Shared Package
ML19309A769 List:
References
NUDOCS 8004010311
Download: ML19309A768 (2)


Text

0 03/24/80 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING APPEAL BOARD In the Matter of

)

)

VIRGINIA ELECTRIC AND POWER COMPANY

)

Docket Nos. 50-338 OL

)

50-339 OL (North Anna Nuclear Power Station,

)

Units 1 and 2)

)

NRC STAFF RESPONSE TO APPEAL BOARD'S MEMORANDUM AND ORDER OF MARCH 3, 1980 On March 3, 1980, the Appeal Board issued a Memorandum and Order in this proceeding, in which it directed the Staff to:

1) furnish a more complete explanation of how the Staff constructed and would justify the crack growth rate curves that it employed in the analysis previously submitted to the Appeal Board and 2) inform the Appeal Board as to how soon the Staff expects to be able to furnish it a more definite statement of whether, and to what extent, the Staff's earlier testimony cn turbine missiles has been affected as a result of the discovery of the disc cracking phenomenon. The Staff's response to the first matter is contained in the attached Affidavit of Warren S. Hazelton, with attachments. With respect to the second question, the Staff has, with one exception, previously indicated that the recent information regarding turbine disc cracking will not appreciably change the Staff's estimate of turbine missile risks for North Anna Units 1 and 2.

See, "Effect of Recent Westinghouse Turbine Cracking Experience on Estimated Historical Turbine Failure Rate," Attachment I to letter from D. Swanson to Appeal Board dated February 19, 1980.

The one key factor that is still undetermined, and which could affect the Staff's testimony, is the frequency of inservice inspec-tion of the North Anna turbines. The Staff position regarding the frequency 8004010311 I

.=

the time that such inspection schedules are developed and incorporated into the licenses as technical specifications for the North Anna units, the Staff will also be able to indicate whether any changes are necessitated in the Staff's testimony regarding the effects of turbine missiles.

The Staff has recently sent out requests for information regarding turbine cracking to licensees of operating reactors. The Staff will evaluate the responses to the questions, to determine whether any of the material contained a

in them is relevant and material to this proceeding.

If relevant and material information is received, it will be forwarded to the Appeal Board.

Respectfully submitted, h & E, f a w n vr Daniel T. Swanson Counsel for NRC Staff Dated at Bethesda, Maryland this 24th day of March, 1980 i

4 0

)

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING APPEAL BOARD In the Matter of

)

)

VIRGINIA EECTRIC AND POWER COMPANY

)

Docket Nos. 50-338 OL

)

50-339 OL (North Anna Nuclear Power Station,

)

Units 1 and 2)

)

AFFIDAVIT OF WARREN S. HAZELTON STATE OF MARYLAND

)

COUNTY OF MONTGOMERY ) SS I, Warren S. Hazelton, do depose and state that:

1.

I am a Section Leader, Engineering Branch, Division of Operating Reactors of the United States Nuclear-Regulatory Commission.

I am responsible for reviewing materials related to aspects of operating nuclear power plants, including the North Anna Unit 1 facility.

A copy of my professional qualifications was previously submitted to the Appeal Board as an attach-ment to the letter from Daniel T. Swanson dated February 19, 1980.

2.

I authored the attached document entitled " Derivation of Turbine Disc Crack Growth Rates for North Anna Unit 1," dated March 24, 1980, with attachments.

3.

I hereby certify that the information contained in this affidavit and attachments is true and correct to the best of my knowledge and belief.

l h(Ne hql Warren S. Hazelton Subscribed and sworn to before me this 24th day of March, 1980

^

J LL.

t Notary /Public My. Commission expires: July 1, 1982 2^^^v>C3t ?>

^