Responds to NRC 800225 Generic Questions Re Westinghouse Low Pressure Turbine Rotors.Actions Necessary to Minimize Stress Corrosion Cracking Will Not Be Known Until Westinghouse Identifies Causes of Cracking
ML19309A767
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 03/24/1980
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
1-030-13, 1-30-13, NUDOCS 8004010301
Download: ML19309A767 (1)


Text

ARKANSAS POWER & LIGHT CO*APANY POST OFHCE BOX 551 LITTLE ROCK. ARKANSAS 72203 (501)371-4000 March 24, 1980 1-030-13 Director of Nuclear Reactor Regulation ATTN:

Darrell G. Eisenhut, Director Operating Reactors U. S. Nuclear Regulatory Commission Washington, D. C.

20555

Subject:

Arkansas Nuclear One - Unit 1 Docket No. 50-313 License No. DPR-51 Westinghouse Low Pressure Turbine Rotor Cracking (File:

0285,1510.1)

Gentlemen:

Your letter of February 25, 1980 requested information concerning Westinghouse Low Pressure Turbine Rotors.

Our responses to the site specific questions were provided in a letter to you dated March 19, 1980. In response to the generic questions, the following is provided.

A letter dated March 14, 1980 to your Mr. Eisenhut from Mr. Schmerling (Westinghouse) provided responses to the generic questions. We concur with the responses provided by Westinghouse to questions I, II, III.A., IV.A.,

IV.B., IV.C., V, VI, VII, and VIII.

Question III.B. asks what actions have been recommended to utilities to minimize stress corrosion cracking. Westinghouse responded that they had developed recommended limits for steam purity.

It should be pointed our that the steam purity limits necessary to prevent stress corrosion cracking (if such limits exist) are not known at this time.

At this point in time, we feel that it is premature to place the blame for stress corrosion cracking on steam purity.

Therefore, our response to question III.B. is that the actions necessary to minimize stress corrosion cracking will not be known until Westinghouse identifies the causes of the cracking.

At that time we will address the action necessary to minimize stress corrosion cracking.

Very truly ours, A

,; / -

/

ff.

u a vDavid C. Trim le Manager, Licensing DCT: MAS:sh 8 0 04 0103cl ucue n vioote soum uriuries sysTe"