Proposed Amend 42 to License DPR-54 Requesting Exemption from 10CFR50 App H,Allowing Operation of Facility W/Surveillance Specimens Removed from Reactor Vessel.Tech Specs Encl
ML19309A667
Person / Time
Site: Rancho Seco
Issue date: 04/08/1976
From: Kaplan D, Mattimoe J
SACRAMENTO MUNICIPAL UTILITY DISTRICT
To:
Shared Package
ML19309A668 List:
References
NUDOCS 8003310641
Download: ML19309A667 (3)


Text

_ _

l N,_C P ru. 55 u.s. NUCLEAR REGULATORY COMMISSION DOCKET NUM!E R tw So '5\\7s

  1. """f'"

NRC DISTRIBUTION FOn PART 50 DOCKET MATERIAL F R O W '. "J "

  • 1 " I'; ' ' ' ? L' ' ' l1 DATE OF OOCUMENT DISTRICT.... SACRAMENTO, C4 Q g q(

NI IO DATE RECElVED J J IMTTIMOE q. g r](

Y)MRIGINAL LETTE n ONOTORIZE D PROP INPUT FOR NUMBER OF COPIES RECEIVED UNC LASSIFI E D i OCOPy i $%g y Qag JESCRIPTION ENCLOSU RE i TR t'OTOR TED 4-8-7 A.... REQf fESTTf'C AN EXEMDTI( '?

TECH SPEC FOR R ANCHO SECO INTT d1..........

FoM TT!E REQf'TRC.??ENT9 0F 10 CPR 50, APPF.NDIX l

H,..

. PROP 09ED ' MOT NO 42....TR%NS THE l

F.0L I,0"T "G...

] b.' L PLANT NAME c hc) di o MU.f[O:'iJ.,

=

l SAFETY FOR ACTION /INFORMATIOP ENVIRO 4.-(4-%

l_

ASSIGNED AD :

ASSIGNED AD :

n ty BRANCH chi 2F : (b)

K g T.h BRANCH CHIEF :

i l'

PROJECT MANAGER:

PROJECT MANAGER :

!)(

LIC. ASST. :

Imam LIC. ASST. :

INTERNAL DISTRIBUTION 1X ( REG FILE 3 SYSTEMS SAFETY PTANT RYSTEMR pmrTpn ten N

NRC PDR MRTNrMAN TFnRsco ERNST M'I&E(D ScHROFnER BENAROYA BALLARD l!V OELD LAINAS SPANdLER K

COSSICK & STAFF ENGINEERING IPPOLITO b

MIPC MAccAny SITE TECH

-l l

CASE KNIGHT OPERATING REACTORS GabbilLL i

IIANAUER SIIMEIL STELLO SIEPP 1

FARLESS PAWLICKI HULMAN j

OPERATING TECH PROJECT MANAGEMENT REACTOR SAFETY 1

EISENHlIT SITE ANAT.YSIS 1

BOYD ROSS T

SHAO VOLIJER

{

P. COLLINS NOVAK i

BAER BUNCH 1

Il0USTON ROSZTOCZY 4

SCHWENCER X

J. COLLINS 1

PETERSON CHECK Y

GRIT'ES KREGER 1

FELTZ l

IIELTEMES AT & I SITE SAFETY & ENVIRC L

SK0vHOLT SALTZMAN ANALYSIS RUTBERG l

DENTON & MULLER

}

n EXTERN AL DISTRIBUTION CONTR OL NUM BEfl F LPDR :lsAc.aArmnTo.CA.

NATL _LA!7 BROOK!!AVEN NATL LAB v TIC y

REG. V-IE ULRIKSON(ORNL) 8008 V NSIC LA PDR

[

ASLB CONSULTANTS

[e ACR3 l(.sWh% SEN.T T

SACRAMENTO MUNICIPAL UTILITY DISTRICT b 6201 S street, Box 15830. Sacramento, California 95813; (916) 452-3211

[] _ ' April 8,1976 il, W

7 q

E" 4

9, Director of Nuclear Reactor Regulation F&

7 At tention :

Mr. Robert W. Reid, Chief Operating Reactors, Branch 4 y" Oly k [/jj h' U. S. Nuclear Regulatory Commission y'

AP2121976> c-Washington, D. C.

20555 D ins,gyron j,p Docket No. 50-312

.5-

  • =i s a.

N Proposed Amendment No. 42 co g

Rancho Seco Nuclear Generating g

Station, Unit No.1

Dear Mr. Reid:

The Sacramento Municipal Utility District has recently been appraised of damage to the reactor vessel material surveillance holder tubes which has occurred in other Babcock & Wilcox reactors.

At this time we are preparing for an inspection of the surveillance holder tubes in Rancho Seco Unit tio.1.

Until the results of this inspection are analyzed, we are not prepared to discuss the details of a fix to these tubes. However, we will desire to operate Rancho Seco Unit No.1 for the remainder of fuel cycle No. I without serveillance capsules and push rods in the surveillance tubes. Therefore, in accordance with 10 CFR 50, Paragraph 50.12, the District is requesting an exemption from the requirements of 10 CFR 50, Appendix H, which will allow operation of Rancho Seco Unit No.1 with the surveillance specimens removed frca the reactor vessel. Also, in accordance with 10 CFR 50, Paragraph 50.90, the District requests the Rancho Seco Unit No. I Technical Specifications be revised to allow surveillance specimen withdrawal at this time for the remainder of fuel cycle No.1.

The attached proposed Technical Specification replacement pages show this change.

During the initial start-up of Rancho Seco Unit No.1, the District installed an experimental device for Babcock & Wilcox to determine the amount of vessel flange rotatiCn and resulting internal clamping forces during heat-up of the reactor and internals.

The District desires to remove this device during the present outage and in so doing will remove one vent valve thermo-couple which was installed in a uaiqua configuration for this experiment.

The District desires the flexi'oility cf operating Rancho Seco Unit No. I without vent valve thermoccupies installed.

s e

2 Mr. Robert W. Reid April 8,1976 Therefore, we are requesting an addition to the Technical Specifications as shown on the second atta hment. This additional Technical Specification will require inspection of the internal vent valves during each refueling outage as described in your letter to the District dated liarch 16, 1976. This will eliminate the necessity to assume a flow penalty in our operating procedures,as is nct; 1equired, as a result of removing the vent valve thermoccuples.

The attached report provides the justification for operation of Rancho Seco Unit fio.1 during the remainder of fuel cycle No. I with the surveillance specimens removed.

Your pronpt attention to this request for exemption and the proposed Technical Specification changes is requested since our present schedule for resumption of operation is April 20, 1976. Two additional signed and notarized originals of this letter and 37 copies are enclosed.

Respectfully submitted, SACRAMENTO MUt1ICIPAL UTILITY DISTRICT 5. ). kKi

/

.. d. Mattimoe Assistant General Manager o

and Chief Engineer i

l N

sh wv DA) 10 S. KAPLAN Ger eral Counsel for Sacramento Muni ipal Utility District Subscribed and sworn to before me this 8th day of April,1976 h

h Sgjy )/g b 53-:F 2:2; Mqtty Mattier,\\ Notary Public in and f r the County of Sacramento, State l

California

=

g C.

? TQ C My Commission Expires January 12, 1980.

' ' * " ~ ~ '

l Attachments Enclosures m -