Text

...

p,j)

L O

l $SMU=

SACRAMENTO MUNICIPAL UTILITY DISTRICT O 6201 S Street, Box 15830, Sacramento, Califomia 95s13; (916) 452-3211 June 6, 1972 Mr. Lawrence D. Low i

Director Directorate of Regulatory Operations U. S. Atomic Energy Commission

  • {

Washington, D. C.

20545 Dear Mr. Lows During a recent AEC audit at Rancho Seco, it was noted that some localized inward bulges on the containment liner had been accepted which were in excess of the allow-able bulges used in the calculations in supplement number l

of the PSAR.

In accord uce with an understanding reached with t

[

the AEC inspector, the enclosed " Report On Inward Bulges of Containment Liner Plate at Rancho Seco Nuclear Generating i

Station" is submitted in accordance with 10CFR50.55. This report demonstrates analytically that the bulges on the liner are acceptable.

Sincerely 3 curs, 4

J.

. Mattimoe Assistant General Manager and Chief Engineer r

Enclosures 25 2 R. W. Smith, Region V L

l L, 008260}

a

1. i

.