SITE INS.TRUCTION NO..Cf'/Mh__.
DISTRhfUTION 6
THE BABC0CK & WILC0X COMPANY RESPONSE REQ'D F OM ___4_ _
POWER GENERATION GROUP h_
lL. C. Rogers - Manager, Site Services, Three Mile Island APPROVED V
From T. F. Scott - Plant Startup Services Section (2519) g ses 66Ls Cust. TMI-2 File No. NSS-6
~
or Ref.
T3.3.1 Subj. Customer Problem Reports Date June 15, 1976 lm.i...........,..................w...,.
In a telephone call on 6/14/76, Stan Maingi requested assistance on three customer problem reports.
Problem:
Pressurizer spray line temperature alarm setpoint in DP 1101-02, Plant Setpoints, does not agree with the latest infomation transmitted to the customer.
Resolution: A copy of the Site Instruction directing the setpoint change has been placed in the file folder for DP 1101-02 along with a note to include it in the next update.
Problem:
The gasket caterial and bolts for the NI detector wells needs to.
V be modified with thicker gaskets and longer bolts similar to TMI-1.
Resolution: Lee Pletke has authorized Raleigh Smith to proceed with a field change for this modification.
Problem:
The low level alarm setpoint for the Boric Acid Mix Tank given in DP 1101-02 is 12 inches. The plant computer list, point #331, specifies a low level alam of 10 inches.
Resolution: The System Design Data Sheet, B&W Drawing 113619C, Rev. 3, shows 12 inches as the alam setpoint for both the computer and annun-ciator. System Change 159, which changed the alam from 10 inches to 12 inches, was incorporated in Rev. 3 to the Design Data Sheet but not to the plant computer list. Please inform the customer that the plant computer alarm should be changed.
TFS:NF cc:
L. R. Pletke R. G. Eurnley be Ac,/ A7,nbk g/,.,em $$,,l,/
J. D. Phinney L. T. Schlomer REVIEWED FOR ACCURACY R. A. Govers D. E. Warden
.J. A. Middleton S. P. Maingi f
R. M. Smith S!GN D:__
3 %.J_ C D AT E : _ _ d_ _[_ _O$ _ __ _ _ _ _ _ _ _ _ _ _ _
800211o[72 f
W.%:& -u -r ygw2seLWW~M &.;,L~:.c,Mh%2%%:w.-
s
=M, ~
2 i?Z.O.PoGERS - 3OM
[ 7" F.Sc o 7 7 v
R.
o IM1 NS9~d bs'8NT 5 7814 TvP 3EA t/lC E 3 m
'~Q'#g C v5 TOME R l'RuBt.sM REDoi?T3
"" g
){.-7g j
... __ m n ~.
PLEASE REPLY TO THE Al l AChtiD 3. e. f.
ORWARD RESPONSE TO MUCLEAD RFevicF
~
AND SUPPORT M ANAGER. LYNCHBORG, VA.
Cysa 0. E di j e
9 y
u v
N% d
? & cr*
a^-L 0x&
N" M<t M
M Ob t
s
\\
WA gn'..
\\
- 1. ~
v g y
RETUR 1 THIS ( PY TO SEf:0E0 o
mo p
eg h 'a,
A n
..n