O Form NRC418 U.S. NUCLE AA AEGULATORY COMMISSICN CERTIFICATE OF COMPLIANCE 10 CFR 71 For Radioactive Materials Packages 1.(al C aficate Numeer 1.fb) evisson No.

1.(c) tf tio No.

1.(d) Pages No. 1.le) otal No. Pages

2. PRE AM8LE 2 la)

This certificate is issued to satisfy Sections 173.393a.173.394.173.395, and 173.396 of the Department of Transportation HA2ardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Copertment of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item $ below, meets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Matenal Under Certain Conditions."

2.fc)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.s. Department of Transportation or other applicable regulatory agencies induding the government of any country through or into which the pacmage will be transported.

s

3. This certificate is issued on the basis of a safety anasysis report of the package design or application-3.tal Prepared by (Name and address):

3.(b)

Title and dentsfication of report or application:

Nuclear Engineering Company Nuclear Engineering Company Application P.O. Box 7246 dated December 21, 1979.

Louisville, KY 40207 3.(c)

Docket No. 7l-6l44 4 CONDITIONS This certificate is conditional uport the fulfilling of the requirements of Subpart O of 10 CFR 71, as applicable, and the conditions specified in item 5 below.

5. Description of Packaging and Authorized Contents. Model Number, Fissile Class. Other Conditions, and

References:

(a) Packaging (1) Model No.: B-2 (2) Description The packaging consists of a rectangular, double-walled box of welded mild steel construction with dimensions of 142 inches by 91 inches by 54 incnes high which encloses secondary containers. The maximum weight of the loaded package is 42,000 pounds.

The double-walled box consists of an outer 1-inch thick steel shell and an inner 2-inch thick steel shell separated by 56 shock tubes, eight on each end, and ten on each of the two sides, top and bottom. The shock tubes are constructed of both 6-inch Schedule 40 and 8-inch Schedule 30 pipe. The tubes are 5 inches in length and are welded to the exterior of the inner box.

~

The cover of the outer box is secured by forty-six,1-1/4 inch diameter high strength bolts. The lid of the inner box is sealed by two lengths of Garlock single lip closure seals and the seal pressure is maintained by l

steel springs which force the seal lip against the walls of the inner box.

i I

8002010 O

Page 2 - Certificate No. 6144 - Revision No. 4 - Docket No. 71-6144 5.

(a) Packaging (continued)

(3) Drawings T;ie packaging is constructed in accordance with Kenasco Corporation Drawing No. 6901-002B and Bill of Material No. 6901-002C.

(b) Contents (1) Type and form of material

. Radioactive material as solids, in normal or special forms packaged within 00T specification 17H, 55-gallon steel drums, or other secondary containers which meets the requirements of Type A_(49 CFR 5173.389(j)) packaging.

(2) Maximum quantity of material per package Not more than Type 8 quantity radioactive material in each secondary container.

6.

The weight of the contents shall not exceed 5,000 pounds.

7.

Dunnage shall be provided in the shipping cask cavity sufficient to prevent movement of the secondary containers relative to the outer packaging under normal or accident conditions.

I 8.

Prior to each shipment, the inner and outer lid gaskets shall be inspected. The gaskets snall be replaced with new Garlock Model 23 Split Klozure if inspection shows any defects or every twelve (12) months, whichever occurs first.

9.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 71.12(b).

10. Expiration date: January 31, 1985.

REFERENCE Nuclear Engineering Company application dated December 21, 1979.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION CMarles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:

JM 0 3 20 4