ML19305E466
| ML19305E466 | |
| Person / Time | |
|---|---|
| Site: | 07109009 |
| Issue date: | 04/30/1980 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML19305E465 | List: |
| References | |
| NUDOCS 8005120493 | |
| Download: ML19305E466 (4) | |
Text
_
8005120
,0
%e '.: c-6* 3 U.S. NUCLEAR REGULAToint CoMMISSloN
[7, CERTIFICATE OF COMPLIANCE For Radioactive Materials Packages
- la) Ca'ti's:ste Nwmber 1.(b) Revision No.
1.(c) Package identification Ne.
1.(d ) Pages No 1.(e) Total No. Pages 9005 7
USA /9009/B( )F 1
4
". P:E 1.N E:.E 2.'ai This certificate is issued to satisfy Sections 173.3934,173.394,173.395 and 173.396 of the Department of Transportation Hazardous V.aterials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149). as amended.
2/.D)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Faferal Regulations Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Cartain Conditions."
2.fc)
This certificate does not relieve the consignor from cornpliance with any requirement of the regulations of the U.S. Department of Transoortation or other applicable regulatory agencies, including the government of any country through or into which the package will be traruported.
3 T-it certficate is issued on the basis of a safety analysis report of the package design cr application-
- 3. Cal Prepared by (Na ne and address):
3.(b)
Title and identification of report or application:
3eneral Electric Company General. Electric Company application dated
?. 0. Box 780 March 12, 1973, as supplemented.
dilminsten, NC 28401
- 3. lei oocket No.
71-9009 4 CONOITCNS This csrti'icate is conditional upon the fulfilling of the requirements of Subpert O of 10 CFFl 71, as applicable, and the conditions specified in ite - 5 below.
!L Descriptitn of Packagirk; and Authorlied Contents, Model Number, Fissile Class other Conditions, and
References:
(a) Packaging (1) Model No.: FL 10-1 (2) Description Two,16-gage 55-gallon drums welded end to end, approximately 68 inches long and 22-1/2 inches in diameter.
The outer drum closure shall be accomplished by at least a 12-gage bolt-locking ring with drop-forged lugs,
)
one of which is threaded to receive at least 5/8-inch diameter bolt and lock nut. The pressure vessel support mechanism consists of wood supports, steel inner sleeve and nut ring to receive the containment vessel, and fire resistant phenolic foam, formed in place to an average finished density of at least 8 pounds' per cubic foot for the main body and 10 pounds per cubic foot for the cap. Gas relief holes shall be provided in the outer steel d rum.
The containment vessel is a 304L stainless steel 5-inch schedule 40 pipe, approximately 53-1/2 inches long, with a 304L stainless steel 1/2-inch thick welded bottom plate and a 304L stainless steel 300 pound slipon flange and blind flange which is fastened by eight, 3/4-inch steel bolts.
Tne flange closure is gasketed by two ficurcelastomer 0-rings with a pressure tap between the two 0-rfags gr cves.
During shipment, the 0-ring grcove pressure tap is sealed witn a pi;e abg with threads wrapped in tefica ta;e. A 1/4-inch stainless 3:ael vaha is screwed into the blind f'.ange of tne containment vessel, Tqe vahe is sealed by a pipe cao D**]O *]D090VM eoM
+MUSU11AL=
Page 2 - Certificate No. 9009 - Revision No. 7 - Docket No. 71-9009 5.
(a) -(2) Description (continued)
(threads wrapped with teflon tape) and is protected by a 2-1/2-inch high section 5-inch Schedule 40 pipe welded to the top of the flange. The packaging has a maximum gross weight of 515 lbs.
i
~ (3) Drawings
~
The FL 10-1 package is described by International Nuclear Company (INCO)
Drawing No. DSD-479-D, Rev. C, and the containment vessel described by INCO Drawing No. DSD-480-D, Rev. C.
The containment vessel seal is described by INCO Drawing No. DED-169-B, Rev. 2.
(b) Contents (1) Type and form of material (i) Uranyl nitrate solutions having a concentration of uranium 235 and uranium 233 not exceeding 350 grams per liter and an H/U-235 atomic ratio not less than 80, provided that the U-233 and plutonium content is not more than 1% of the U-235 content; or (ii) Uranyl nitrate solutions having a combined concentration of uranium 233 and uranium 235 not exceeding 250 grams per liter and an H to fissile material atomic ratio not less than 80 provided (1) the U-233 content is not greater than 20% of the combined U-233 and U-235 content, and (2) the plutonium content is not more than 1% of the combined U-233 or U-235 content; or i
(iii) Plutonium nitrate solutions having a concentration not exceeding 250 grams fissile plutonium per liter; or (iv)
Uranyl sulfate solution (UO 50:,) containing uranium-235; or 2
(v) Dry compounds and mixtures of fissile plutonium-uranium-235; or (vi) Mixed U-Pu oxide interspersed with graphite er silicon carbide plus plastic packing material.
(2) Maximum quantity of material per package Plutonium in excess of twenty (20) curies per package must be in the form of metal, metal alloy, or reactor elements; or must be in accordance with Item 9 below; and:
(i) For the contents described in 5(b)(1)(i), (ii), and (iii):
Maximum decay heat load not to exceed 21 watts, and 10.5 liters of soluticn.
Page 3 - Certificate No. 9009 - Revision No. 7 - Docket No. 71-9009 5.(b) Contents (continued)
(ii)
For the contents described in 5(b)(1)(iv):
Maximum decay heat load not to exceed 18 watts and 950 grams fissile material.
(iii) For the contents described in 5(b)(1)(v):
Maximum decay heat load not to exceed 30 watts, and 4.5 kilograms fissile material.
(iv)
For the contents described in 5(b)(1)(vi):
Maximum decay heat load not to exceed 10 watts and 300 grams fissile material.
(c) Fissile Class I
6.
The solution contents of the package shall be contained with a bottle having one of the following specifications:
(1) Slit vent polyethylene bottle per Drawing No. CAPE-ll70-37, (ii) Duo-vent polyethylene bottle per Nuclear Fuel Services, Inc., Specification U-l and Drawing No. 58-U-740, or (iii) Stainless steel bottle as shown on General Electric Company Drawing Nos. FRO-140 and FR0-140A.
- 7.. The polyethylene bottles may be packaged within the metal inner container described by Chester-Jensen Company, Inc., Drawing Nos.1092M-1,1093M-1,1095M-1 and 1096M-1, Issue 1, dated April 26, 1971.
8.
The packaging for the polyethylene bottles shall include a flexibile restraining device (such as recommended in ARH-1819 " Vibration Testing of L-3 and L-10 Shipping Containers") placed between the cap assembly of the polyethylene bottle and the closure flange of the pressure vessel to assure that the polyethylene bottle will vibrate at the same frequency as the pressure vessel during transport.
9.
Dry compounds and mixtures which shall be packaged within sealed metal cans or DOT Specification 2R containers (49 CFR 5178.34); and placed within an inner container constructed and leak tested as specified on General Electric Illustration AFL 1105.
Following the gas leak testing specified on the Illustration, all inner container
~
welds shall be leak tested using a liquid penetrant method in accordance with Article 6,Section V, ASME Code. Alternatively, the inner container shown in the Illustration may be constructed of 300 series stainless steel pipe with an outside diameter of 4.500 + 0.015 inches with a wall thickness ranging between 0.095 and 0.120 inch.
l
- 10. Apprcoriate steps shall be taken to assure that f:om the time of sealing to the time of delivery to the consignee, the pressure in the containment vessel will not excesd a0 psig.
Sa;e 4 - Certificate No. 9009 - Revision No. 7 - Docket No. 71-9009 1.
Prior to each shipment of more than Type A quantities of radioactive material, the space between the double 0-ring seal shall be tested at 100 psig and leak
-de ection performed by a method capable of detecting a leak greater than 10 3 atm cc/sec at standard temperature and pressure.
No package with a detectable leak shall be delivered to a carrier for transport.
- 12. In addition to the requirements of Subpart D of 10 CFR 71, a test shall be performed on each containment vessel and associated 1/4-inch SS valve (without its associated pipe cap) initially and once each year at 300 psig and the leak detection performed by a method capable of detecting a leak greater than 10 6 atm cc/sec at standard te perature and pressure. Any chamber that fails to pass the test shall be withdrawn fr:m service and repaired to meet the test.
- 13. The fire resistant phenolic foam shall be in accordance with AEC Materials and Equipment Specification SP-9 or as modified by ORGDP Reports K/TL-729 and K/P-6567S.
- 14. The package authorized by this certificate is hereby approved for use under the general license provisions of 10.CFR 571.12(b).
- 15. Expiration date: August 31, 1983.
REFERENCES Ger.eral Electric Company application dated March 12, 1973.
Supplemants dated: April 13,1973; March 21,1974; and April 16, 1979.
liestinghouse Electric Corporation supplements dated: October 3, 1979; and March 11, 1980.
1 E,ab:ock and Wilcox Company supplement dated: April 17,1980.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION M.T L Y
\\
Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety APR 3 01980 2 t,.
l
-