Advises That IE Bulletin 79-03A, Longitudinal Weld Defects in ASME SA-312 Type 304 Stainless Steel Pipe, Was Sent to Listed Utils on 800404 for Action
ML19305E297
Person / Time
Site: Dresden 
Issue date: 04/07/1980
From: Carroll D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 8004230304
Download: ML19305E297 (1)


Text

TIC

'o UNITED STATES 8'

NUCLEAR REGULATORY COMMISSION n

f.-

E REGION 111 b[

799 ROOSEVELT ROAD o,

o GLEN ELLYN, ILLINOIS 6o137 APR 7 soo MEMORANDUM FOR: Those on Attached List FROM:

Dorothy E. Carroll, Acting Chief, Administrative Branch

SUBJECT:

IE BULLETIN NO.79-03A The attached IE Bulletin No.79-03A titled " Longitudinal Weld Defects in ASME SA-312 Type 304 Stainless Steel Pipe" was sent to the following licensees on April 4,1980 for action.

American Electric Power Service Corporation Indiana and Michigan Power Company D. C. Cook 1, 2 (50-315, 50-316)

Cincinnati Gas & Electric Company Zimmer (50-358)

Cleveland Electric Illuminating Company Perry 1, 2 (50-440, 50-441)

Commonwealth Edison Company Braidwood 1, 2 (50-456, 50-457)

Byron 1, 2 (50-454, 50-455)

Dresden 1, 2, 3 (50-10, 50-237, 50-249)

La Salle 1, 2 (50-373, 50-374)

Quad-Cities 1, 2 (50-254, 50-265)

Zion 1, 2 (50-295, 50-304)

Consumers Power Company Big Rock Point (50-155)

Midland 1, 2 (50-329, 50-330)

Pal!.sades (50-255)

Dairyland Power Cooperative LACBWR (50-409)

Detroit Edison Company Fermi 2 (50-341)

Illinois Power Company Clinton 1, 2 (50-461, 50-462) l s00423 %

I l

e Those on Attached List s Iowa Electric Light & Power Company Duane Arnold (50-331)

Northern Indiana Public Service Company Bailly (50-367)

Northern States Power Company Monticello (50-263)

Prairie Island 1, 2 (50-282, 50-306)

Public Service of Indiana Marble Hill 1, 2 (50-546, 50-547) l Toledo Edison Company Davis-Besse 1 (50-346)

Union Electric Company Callaway 1, 2 (50-483, 50-486)

L Wisconsin Electric Power Company Point Beach 1, 2 (50-266, 50-301)

Wisconsin Public Service Corporation Kewaunee (50-305)

-) -

Ah l

orothy arroll, Acting ief Administra ive Branch

Enclosure:

IE Bulletin No.79-03A l

l

5 Addressees - Memorandum dated April 4, 1980 Central Files Reproduction Unit NRC 20b

SSINS No:

6820 i

Accession No.:

UNITED STATES 8002280644 NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 7

April 4, 1980 l

IE Bulletin No.79-03A LONGITUDINAL WE'_0 DEFECTS IN ASME SA-312, TYPE 304 STAINLESS STEEL PIPE Description of Circumstances:

IE Bulletin No. 79-03 required the licensee to determine if ASME SA-312, Type i

304 pipe manufactured by Youngstown Welding and Engineering Company is in use or planned for use in safety-related systems.

Since the issuance of IE l

Bulletin 79-03 on March 12, 1979, subsequent findings indicate additional information and clarification is needed to resolve the SA-312 issue.

It has been determined that conventional ultrasonic testing (UT) and radio-graphic testing (RT) techniques (as required by ASME Section III) are not i

adequate to detect centerline lack of weld penetration (CLP).

Conventional radiography and UT examinations may detect the presence of CLP under special conditions, but neither can be considered reliable enough to detect CLP even when significant percentages exist.

Based upon the above and previous findings during inspections at Youngstown it has been determined that the Youngstown Welding and Engineering Company did comply with the ASME Code requirements, but that the Code NDE requirements are deficient.

Consequently any manufacturers' SA-312, Type 300 Series, austenitic stainless steel fusion welds may contain undetected CLP.

This problem is generic to all welded SA-312/A-312 material and is not restricted to material manufactured by the Youngstown Welding and Engineering Company.

The NRC has verified that the CLP condition also exists in the SA-312 and/or A-312 fusion welded pipe manufactured by ARMCO's Advanced Materials Division, the SWEPC0 Tube Corporation and Crucible's Trent Tube Division.

These companies are known to have supplied SA-312 and/or A-312 material for nuclear applications and are now included within the scope of this Bulletin.

Several Licensee's responses to the IE Bulletin 79-03 were inadequate.

The responses were inadequate because they were based on the purchase order NDE requirements rather than the information requested in the Bulletin.

An actual example of an inadequate response was as follows:

Radiography of a circum-ferential weld seam revealed CLP in the longitudinal seam of a section of SWEPC0 fusion welded pipe.

The licensee did not believe the case was reportable if the original NDE requirements for the SWEPC0 pipe did not require volumetric examination.

This CLP problem is considered by the NRC to be a significant deficiency which requires extensive evaluation and could result in repair or replacement of pipe and/or fittings.

IE Bulletin No.79-03A April 4, 1980 g

Page 2 of 3 The information requested in this revised Bulletin is'to be provided without regard to the purchase order NDE requirements or any subsequent NDE performed for or by the licensee.

The information requests in this Bulletin supersede the requests for information in the IE Bulletin 79-03.

I The NRC staff position on this issue and any other case where defects or deficiencies are discovered in safety-related components is as follows:

Regardless of the circumstances under which potential deficiencies or potential defects in safety-related components are discovered the matter shall be identi-fied, evaluated, dispositioned documented and reported in strict accordance with f

the appropriate Federal Regulations. Although the ASME Code rules arid requirements may be used when appropriate to evaluate defect" or deficiencies and to justify and accept the existence of a defect or deficieJcies, the Code can not be used as justification for not reporting the difect, oc'iciency and circumstances to the NRC when that defect or deficiency his been idt/***ied by the NRC as a potential generic problem. When the lice 1see, his age.,

endor discovers a defect or deficiency that may be a generit problem or a >:2.ificant lone deficiency a conservative position shall ba adopted regarding the reporting of the situation to the NRC.

I For those power reactor facilities that have the subject pipe installed the action identified in this Bulletin is limited to identifying the specific applications and providing information related to the structural integrity of the pipin~g components.

Additional guidance related to NDE's and/or precau-tionary or corrective actions will be provided in a later Bulletin revision if necessary.

Revised action to be taken by Licensees and Permit Holders:

For all power reactor facilities with an operating license or a construction permit:

r 1.

Determine whether SA-312 or A-312, Type 300 Series fusion welded pipe is in use or planned for use in safety-related systems subject to design stresses greater than 85 percent of the Code allowable stresses.

For the i

purpose of this clack the actual wa'll thickness of the piping products will be considered aoiquate if tSe code requirements for pressure design of the piping products o*e satisfied using 85 percent of the maximum allowable strsss at the des ign '.emperature.

2.

For those piping components using greater than 85 percent of the l

allowable stresses identi/y tSe application of the piping including the system, pipe location, pipe size, pipe configuration (elbow, tee), design pressure / temperatu e raqu'rements and the manufacturer.

t 3.

For those facilities under construction and where access permits, the ends of all safety-related SA-312 and A-3'.2 fusion welds should be etched to determine if CLP exists.

Identify the manufacturer and the degree of CLP as a percentage of the pipe wall thickness.

l

,,--.a, a

-a

t IE Bulletin No.79-03A April 4, 1980 1

Page 3 of 3 4.

For facilities with an operating license, a report of the above information shall be submitted within 120 days of receipt of this Bulletin.

5.

For facilities with a construction permit, a report of the above information shall be submitted within 120 days of receipt of this Bulletin.

Reports should be submitted to the Director of the appropriate NRC Regional i

Office and a copy should be forwarded to the NRC Office of Inspection and Enforcement, Division of Reactor Construction Inspection, Washington, D.C., 20555.

i Appro',ed by GAO, B180225 (R0072); clearance expires 7f31/80.

Approval was given under a blanket clearance specifically for identified generic problems.

g

~

i l

l l

L I

l l

1

IE Bulletin No.79-03A Enclosure k

April 4, 1980 RECENTLY ISSUED IE BULLETINS 1

Bulletin Subject Date Issued Issued To No.

80-06 Engineered Safety Feature 3/13/80 All power reactor (ESF) Reset Controls facilities with an OL 80-05 Vacuum Condition Resulting 3/10/80 All PWR power reactor In Damage To Chemical Volume facilities holding Control System (CVCS) Holdup OLs and te those with Tanks a CP s79-01B Environmental Qualification 2/29/80 All power reactor of Class IE Equipment facilities with an OL 80-04 Analysis of a PWR Main 2/8/80 All PWR reactor facilities

-Staam Line Break With holding OLs and to those Continued Feedwater nearing licensing Addition 80-03 Loss of Charcoal From 2/6/80 All holders of Power Standard Type II, 2 Inch, Reactor OLs and cps Tray Adsorber Cells 80-02 Inadequate Quality 1/21/80 All BWR licenses with Assurance for Nuclear a CP or OL 80-01 Operability of ADS Valve 3/11/80 All BWR power reactor Pneumatic Supply facilities with and OL 79-01B Environmental Qualification 1/14/80 All power reactor of Class IE Equipment facilities with an OL 79-28 Possible Malfunction of 12/7/79 All power reactor Namco Model EA 180 Limit facilities with an Switches at Elevated OL or a CP Temperatures 79-27 Loss Of Non-Class-1-E 11/30/79 All power reactor Instrumentation and facilities holding Control Power System Bus OLs and to those l

During Operation nearing licensing 79-26 Baron Loss From BWR 11/20/79 All BWR power reactor Control Blades facilities with an OL

-