ML19305D961

From kanterella
Jump to navigation Jump to search
Forwards Supplemental Info to 790529 Final Deficiency Rept Re Pressurizer Relief Piping Support
ML19305D961
Person / Time
Site: Sequoyah 
Issue date: 04/11/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19305D962 List:
References
NCR-79-5-8, NUDOCS 8004170026
Download: ML19305D961 (1)


Text

,

TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 37401 400 Chestnut Street Tower II April 11, 1980 i

Mr. James P.

'Reilly, Director

(

Office of Insp tion and Enforcement U.S. Nuclear Reg atory Commission i

Region II - Suite 3100 101 Marietta Stree i

Atlanta, Georgia 3 303

Dear Mr. O'Reilly:

SEQUOYAH NUCLEAR PLANT UNIT 1 - PRESSURIZER RELIEF PIPING SUPPORT -

NCR SWP 79-S SUPPLEMENTAL INFORMATION The subject deficiency was initially reported to NRC-01E Inspector W. T. Cottle on May 29, 1979, in accordance with 10 CFR 50.55(e).

A final report on this item was transmitted to you in a letter from J. E. Gilleland dated June 22, 1979. Enclosed is supplemental informa-tion on the pressurizer relief line draw bead weld as requested in a meeting with the NkC staff on March 13, 1980.

If you have any questions concerning this matter, please get in touch with D. L. Lambert at FTS 854-2581.

l Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety i

Enclosure cca Mr. Victor Stallo, Jr., Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 6

l An Eauat Opportumty Employer 80041700 3,6

.