_

Scs

,(p k8 88%g,k t

UNITED STATES NUCLEAR REGULATORY COMMiss!ON y 't ) g g

WASHINGTON. O. C, 20555

%....).)

mum Docket No. 50-201 MEMORANDUM FOR: Leland C. Rouse, Chief Advanced Fuel and Spent Fuel Licensing Branch t

FROM:

Charles J. Haughney Advanced Fuel and Spent Fuel Licensing Branch

SUBJECT:

MEETING

SUMMARY

LICENSEES:

Nuclear Fuel Services. Inc. (NFS) and New York State Energy Research and Development Authority (NYSERDA)

(License No. CSF-1)

FACILITY:

Western New York Nuclear Service Center, West Valley, New York

Purpose:

To discuss the progress of NFS efforts to process technical data useful for future decontamination and decommissioning of the West Valley facility.

Place and Date: Nuclear Regulatory Commission (NRC), Office of Nuclear Material Safety and Safeguards, Silver Spring, Maryland; February 13, 1980

Participants:

Please see attached list.

Index of Facility Design Data The index for plant area 7, Liquid Waste Treatment, is complete; and a copy of the area 7 index is attached. The next portion of the index to be worked will be plant area 15, Common Facilities. Area 15 design data constitutes the greatest amount of design data for any plant area.

Report of Decontamination History The section of the decontamination history that describes decontamination efforts in the mechanical cells is still under preparation.

This section of the report should be completed by the time of the next meeting..

0 414 Op()

N1 Leland C. Rouse

-2 Next Meeting The next meeting is tentatively scheduled for 1:30 p.m., Wednesday, April 16,1980 at the NRC offices in Silver Spring, Maryland, t

Charles J. Hau hney Advanced Fuel and Spent Fuel Licensing Branch Division of Fuel Cycle and Material Safety

Enclosures:

1.

Area 7 Index 2.

Participant list

DRAFT 2/80 AREA 7 - LIQUID WASTE TREAT!1ENT AND ACID RECOVERY 1.0 PROCESS 1.1 Bechtel Drawings 7R-A-1 P&ID, Rework and Waste Evaporation 7R-A-2 P&ID, General Purpose Evaporator and Acid Recovery 70-A-8 Penetration Schedule, LWC-North Wall 7D-A-9 Penetration Schedule, LUC-East Wall 70-A-10 Penetration Schedule, LWC-South Wall 70-A-11 Penetration Schedule, LWC-West Wall.

70-A-12 Penetration Schedule, LWC-Ceiling 1.2 NFS Drawings 70-A-lli Acid Recovery 'Bottons, det System 78-A-ll36 Receiver Locations in ARC 7D-A-ll37 Flow Diagram Acid Fractionator 2.0 LAYOUTS 2.1 Bechtel Drawinns 15A-A-ll7 General Arrg't at Elev 100'0" 15A-A-ll8 General Arrg't at Elev 114'6" 15A-A-119 General Arrg't at Elev 131' 15A-A-120 General Arrg't at Elev 144' 15A-A-122 General Arrg't Process Bldg Section #1 15A-A-123 General Arrg't Process Bldg Section #2 15A-A-124 General Arrg't Process Bldg Section #3 15A-A-125 General Arrg't Process Bldg Section #4 15A-A-126 General Arrg't Process Bldg Section #5 15A-A-127 General Arrg't Process Bldg Section #6 15A-A-143 Equip Arrg't CPC Sections 15A-A-144 Equip Arrg't CPC Elevations 15A-A-145 Equip Arrg't CPC Plan 15A-A-155 Equip Arrg't ARC Schenatic Elevation 15A-A-156 Equip Arrg't LWC Plan 15A-A-157 Equip Arrg't LWC Section 15A-A-158 Equip Arrg't OGC & ARC Plan 110'6" 15A-A-159 Equip Arrg't OGC & ARC Plan 128'3" 15A-A-160 Equip Arrg't OGC & ARC Plan 143' 15A-A-161 Equip Arrg't 0GC & ARC Plan Above 144' 15A-A-169 Equip Arrg't Hot Acid Cell Plan 15A-A-170 Equip Arrg't Hot Acid Cell Schematic Elev

DRAFT 2/80

. 3.0 EQUIPMEflT 3.1 Bechtel 3.1.1 7C-1 High Level Waste Evaporator Drawings 78-C-4 Support Details (Bechtel) 05-7C-1 Data Sheet (Bechtel) 2A-16911 Peerless Separator (Vendor) 15C-2-1 Setting Plans 7C-1 (Vendor) 15C-2-21 3" Titanium Connector (Vendor) 15C-2-22 4" Titanium Connector (Vendor) 15C-2-26 Coils and Coil Support (Vendor) 15C-2-69 Drawing Index 7C-1 (Vendor) i 15C-2-70 Air Sparger Details (Vendor) 15C-2-71 Name Plate (Vendor) 15C-2-72 Bent Tube fiark E (Vendor) 15C-2-73 Bent Tube Mark F (Vendor) 15C-2 Bent Tube liark H (Vendor) 15C-2-75 Bent Tube fiark G (Vendor) 15C-2-76 Pad & Flange for Coil Connection (Vendor) 15C-2-77 tiozzle Overflow Baffle (Vendor) 15C-2-106 Bent Tubes in flozzle G (Vendor) 15C-2-107 Bent Tubes in flozzle G (Vendor) 15C-2-116 Top Trunnion Detail (Vendor) 15C-2-117 Pattom Trunnion Detail (Vendor) 15C-2-120

~.denserDetails(Vendor) 15C-2-124 W yable Eductor (Vendor) 15C-2-125 special Stud & Nut (Vendor) 15C-2-129 Shop Procedure (Vendor) 15C-2-130 Balancing Procedure (Vendor) 15C-2-132 Overall Dimensions Connectors (Vendor) i 15C-2-136 Connector Locations (Vendor) 15C-2-138 Alterations to Condenser (Vendor) 15C-2-140 As-Built Dimensions (Vendor)

Enecifications 4413-A-1 General 4413-C-1 Titanium Equipment 4413-C-2 Stainless Equipment 4413-C-502 Fabrication of Pressure Vessels Material Requisition 4413-15C-2 Evaporators k

DRAFT 2/80 3.1.2 7C-3 Acid Fractionator Drawings 7B-C-2 Acid Fractionator Plant & Elevation (Bechtel) 7C-5-1 Plans & Elevations (Vendor) 7C-5-2 Skirt Details (Vendor)

~

7C-5-3 18" Manhole (Vendor) 7C-5-4 Stub flozzle Details (Vendor) 7C-5-5 Stub flozzle Details (Vendor) 7C-5-10 Welding Procedure (Vendor) 7C-6-1 Arrg't of Trays (Vendor) 7C-6-2 Assembly of Trays 1 thru 5 (Vendor) 7C-6-3 Assembly of Trays 6 thru 13 (Vendor) 7C-6-4 Installation Instructions (Vendor) 7C-6-5 Crating Procedure (Vendor) 7C-6-6 Shipping Statement (Vendor) i Specifications 4413-A-1 General 4413-C-1 Stainless Steel Equipment 4413-C-502 Fabrication of Vessels Material Requisitions 4413-7C-5 Acid F.ractionator 4413-7C-6 Trays for 7C-3 3.1.3 7C-4 Rework Evaporator Drawings 78-C-3 Support Details for 7E-8 on 7C-4 (Bechtel)

DS-7C-4 Data Sheets (Bechtel) 15C-2-28 Spiral Coil Details (Vendor) 15C-2-88 Drawing Index and Material List (Vendor) 15C-2-89 Name Plate Details (Vendor) 15C-2-90 Bent Tube Mark C (Vendor) 15C-2-91 BentTubeMarkE(Vendor) 15C-2-92 BentTubefiarkF(Vendor) 15C-2-93 Bent Tube fiark H (Vendor)

I 15C-2-94 CondenserSupport(Vendor) 15C-2-95 Air Sparger Details (Vendor) 15C-2-100 Welding Procedure (Vendor) 15C-2-108 flozzle Mark J (Vendor) 15C-2-109 Bent Tubes in Nozzle G (Vendor) 15C-2-110 Bent Tubes in flozzle H (Vendor) 15C-2-118 Bottom Trunnion Detail (Vendor) 15C-2-119 Top Trunnion Detail (Vendor) l 15C-2-123 Attaching Connectors (Vendor) 15C-2-125 Special Studs a fluts (Vendor) 15C-2-127 Eductor Assembly (Vendor) 1 15C-2-128 Removable Eductor (Vendor)

DRAFT 2/80 15C-2-129 Shop Procedure (Vendor) 15C-2-130 Balancing Procedure (Vendor) 15C-2-131 Overall Dimensions Remote Connectors (Vendor) 15C-2-137 Connector Locations (Vendor) 15C-2-141 As-Built Dimensions (Vendor) 2A-16914 Separator (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Equipment 4413-C-502 Fabrciation of Pressure Vessels Materials Requisitions 4413-7C-5 Acid Fractionator 4413-7C-6 Trays for Acid Fractionator 7C-3 3.1.4 7C-5 General Purpose Evaporator Drawings 2A-16913 Separator (Vendor)

DS-7C-5 Data Sheet (Bechtel) 15C-2-10 General Purpose Evaporator (Vendor) 15C-2-79 Drawing Index & Material List (Vendor) 15C-2-80 Hame Plate (Vendor) 15C-2-81 BentTubeflarkC(Vendor) 15C-2-82 Bent Tube liark D (Vendor) 15C-2-83 Bent Tube Mark D2 (Vendor) 15C-2-84 Gaskets (Vendor) 15C-2-85 Air Sparger (Vendor) 15C-2-86 Bundle Details (Vendor) 15C-2-87 Shop Details (Vendor) 15C-2-135 As-Built Dimensions (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Equipment 4413-C-502 Fabrication of Pressure Vessels Material Reaufsition 4413,-15C-2 Evaporators 3.1.5 7D-1 High Level Waste Evaporator Feed Tank Drawinas 7B-D-2 H.L. Waste Evap Feed Tank (Bechtel) 150-17-20 Plans & Elevations (Vendor) l 15D-17-21 HeliumLeakTestProc(Vendor) i 150-17-22 Fabrication Tolerances (Vendor) l 150-17-35 Material Testing Requirements (Vendor) l

DRAFT 2/80 :

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Equipment 4413-X-1 Surface Preparation 4413-C-504 Documents Required Material Requisition 4413-150-17 Process Tanks 3.1.6 7D-2 Low Level Waste Evaporator Feed Tank Drawinas

[

7B-D-3 L.L. Waste Evap Feed Tank (Bechtel) 150-2-4 ElevationsandGeneralNotes(Vendor)

Specifications 4413.A-1 General 4413-C-2 Stainless Steel Equipment 4413-X-1 Surface Preparation 4413-C-504 Documents Required Material Requisition 4413-15D-2 Process Tanks

{

3.1.7 7D-3 Acid Fractionator Feed Tank Drawings l

78-D-4 Acid Fractionator Feed Tank (Bechtel) 15D-38-4 Section Elevation and Notes (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Vessels Material Requisition 4413-15D-3 Stainless Steel Vessel's 3.1.8 7D-4 High Level Waste Neutralizer Tank Drawings 78-D-5 High Level Waste Neutralizer Tank (Bechtel) 70-19-1 Internal Guide Tube (Vendor) 70-19-2 Pipe Support Legs (Vendor) 7D-19-3 Stub Nozzle Details (Vendor) 70-19-4 General Arrg't and Notes (Vendor) 70-19-6 Base and Guide Parts (Vendor) 70-19-7 Eductor liatch (Vendor) 70-19-8 Trunnions and Misc Details (Vendor) 70-19-9 Spec Studs and Nuts (Vendor)

DRAFT 2/80 Specifications 4413-A-1 General 4413-C-2 Stainless Steel Tanks Material Requisitions 4413-70-19 Process. Tanks CPC 3.1.9 70-5 Recovered Acid Storage Tank Drawings 78-D-6 Recovered Acid Storage Tank (Bechtel) 15D-4-1 Stub Nozzle Details (Vendor) 150-4-6 Elevations Sections & Gen Notes (Vendor) 150-4-7 LR & DR Connections (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Tanks 4413-X-1 Surface Preparation 4413-C-504 Documentation Requirements Material Requisition 4413-150-4 Process Tanks 3.1.10 70-6 Weak Acid Catch Tank Drawings 7B-D-7 Weak Acid Catch Tank (Bechtel) 15D-3B Plans Elevation and Gen Notes (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Tanks 4413-X-1 Surface Preparation gsf al Requisition i

4413-150-3 Process Tanks 3.1.11 7D-8 Rework Evaporator Feed Tank Drawings 70-D-8 Rework Evaporator Feed Tank (Bechtel) 150-2-5 Plans Elevations & Gen Notes (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Tanks 4413-C-504 Documentation Requirements

DRAFT 2/80 ;

Haterial Requisition 4413-150-2 Process Tanks 3.1.12 70-10 Low Level Waste Accountability Tank Drawings L.L. Waste Accountability Tank (Bechtel) 78-D-10 70-19-1 Internal Guide Tubes (Vendor)

Guide Parts (Vendor) )

70-19-6 Eductor Hatch (Vendor 7D-19-7 Trunnions and Misc Details (Vendor) 70-19-8 70-19-9 Studs & tluts (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Tanks -

Material Reauisition 4413-70-19 Process Tanks CPC 3.1.13 7D-11 Hot Acid Storage Tank Drawings _

7B-D-11 Hot Acid Storage Tank (Bechtel) 15D-4-1 Stub Nozzle Details (Vendor) 15D-4-7 Level & Density Connections (Vendor) 150-4-8 3S Sample Connections (Vendor) 15D-4-9 General Arrg't and flotes (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Tanks Material Requisition 4413-15D-4 Process Tanks 3.1.14 70-12 Hot Acid Batch Tank Drawings 78-D-15 Hot Acid Batch Tank (Bechtel) 150-4-1 Stub Nozzle Details (Vendor) 15D-4-8 3S Sample Connections (Vendor) 15D-4-10 General Arrg't and Notes (Vendor)

Snecifications 4413-A-1 General 4413-C-2 Stainless Steel Tanks 44'3-X-1 Surface Preparation 4413-C-504 Documentation Requirements I

DRAFT 2/80 t Material Requisition i

4413-15D-4 Process Tanks 3.1.15 70-13 Laundry and Analytical Drains Catch Tank Drawings 78-D-12 Laundry and Analytical Drain Catch Tank (Bechtel) 15D-2-10 Welding Procedure (Vendor)

(

150-2-18 Catch Tank (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Tanks 4413-C-504 Documentation Requirements Material Requisition 4413-150-2 Process Tanks 3.1.16 70-14 Hot Analytical Cell Drain Catch Tank i

Drawinns 7B-D-13 Hot Analytical Cell Drain Tank (Bechtel) 70-11-1 Stub Nozzle Details (Vendor) 70-11-2 Pipe Support Legs (Vendor) 70-11-3 Plans Elevations and General Notes (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Material Requisition 4413-70-11 Hastelloy "C" Process Tank 3.1.17 7E-2 Acid Fractionator Reboiler Drawings DS-7E-2 Data Sheet (Bechtel) 15E-1A-6 AcidFractionatorReboiler(Vendor) 15E-1A-10 Qualification (Vendor) 15E-1A-12 Q-1 Form (Vendor) 15E-1 A-13 Reboiler Material Sheet (Vendor) 15E-1A-14 Reboiler Details (Vendor) i Specifications 4413-A-1 General 4413-E-1 Tubular Heat Exchangers Material Requisitiori 4413-15E-l Heat Exchangers

DRAFT 2/80 3.1.18 7E-3 Acid Fractionator Condenser Drawings DS-7E-3 DataSheet(Bechtel) 15E-2-1 Condenser Arrg't (Vendor) 15E-3-3 Acid Fractionator Reboiler (Vendor)

Specifications 4413-A-1 General 4413-E-1 Tubular Heat Exchangers Material Requisition 4413-15E-2 Heat Exchangers 3.1.19 7E-4 High' Level Waste Evap Heating Coil Drawings DS-7E-4 Data Sheet (Bechtel)

Specifications 4413-A-1 General 4413-C-1 Titaniun Equipment Material Requistion' 4413-15C'-2 Evaporators 3.1.20 7E-5 High Level Waste Condenser Drawings DS-7E-5 Data Sheet (Bechtel) 15C-2-9 High Level Waste Evap) Condenser (Vendor) 15C-2-51 Drawing Index (Vendor 15C-2-52 Tube Layout (Vendor) 15C-2-53 Channel to Fixed Tube Layout (Vendor) 15C-2-54 ShopDetails(Vendor)

Soecifications 4413-A-1 General 4413-C-1 Titanium Equipment 4413-C-2 Stainless Steel Equipment Material Requisition 4413-15C-2 Evaporators e

DRAFT 2/80 i t

3.1.21 7E-8 Rework Evaporator Condenser Drawings DS-7E-8 DataSheet(Bechtel)

Rework Evaporator Condenser (Vendor) )

15C-2-11 Drawing Index and Mat Listing (Vendor 15C-2-42 15C-2-43 Tube Layout (Vendor) 2 15C-2-44 Condenser (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Equipment Material Requisition 4413-15C-2 Evaporators l

3.1.22 7E-9 Acid Fractionator Vacuum Inter-Condenser Drawings DS-7E-9 DataSheet(Bechtel) 15E-2-1 Condenser Arrg't (Vepdor) 15E-2-5 Acid Fractionator det Ejectors (Vendor) 15E-2-6 Arrg't of Vacuum Equipment (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Equipment l

Material Reouisition 4413-15E-2 Exchangers 3.1.23 7E-10 Acid Fractionator Vacuum After-Condenser Drawings DS-7E-10 Data Sheet (Bechtel) 15E-2-1 Condenser Arrg't (Vendor) 15E-2-4 Acid Fractionator After Condenser (Vendor) 15E-2-6 Arrg't of Vacuum Equipment (Vendor)

Soecifications 4413-A-1 General l

4413-C-2 Stainless Steel Equipment l

Material Requisition 4413-15E-2 Condensers

DRAFT 2/80 3.1.24 7E-11 Vaporizer Bottoms Cooler r

Drawings DS-7E-11 DataSheet(Bechtel) 15E-1C-1 Welding (Vendor) 15E-1C-2 Vaoorizar Bottoms Cooler (Vendor) 15E-1C-4 Vaporizer Bottoms Cooler (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Equipment Material Requisition 4413-15E-1C Coolers 3.1.25 7E-12 Acid Fractionator Bottoms Cooler Drawinns j

DS-7E-12 DataSheet(Bechtel) 15E-1C-3 Acid Fractionator Cottoms Cooler (Vendor) i 15E-1C-5 Acid Fractionator Bottoms Cooler (Vendor) l Specifications 4413-A-1 General 4413-C-2 Stainless Steel Equipment Material Requisition 4413-15E-1C Coolers 3.1.26 7E-13 General Purpose Evaporator Condenser Drawings i

DS-7E-13 Data Sheet (Bechtel) 15C-2-12 General Purpose Evaporator Cond (Vendor) i 15C-2-47 Drawing Index & liat Index (Vendor) l 15C-2-48 Shop Details (Vendor) l l

l i

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Equipment 1

Material Requisition 4413-15C-2 Evaporators v

DRAFT 2/80,

3.1.27 7E-14 General Purpose Evaporator Reboiler Drawings DS-7E-14 DataSheet(Bechtel) 15C-2-86 Bundle Details (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Equipment Material Requisition 4413-15C-2 Evaporators 3.1.28 7E-15 Rework Evaporator Heating Coil Drawings DS-7E-15 Data Sheet (Bechtel) 15C-2-28 Coil Details (Vendor)

Specifications 4413-A-1 General 4413-C-2 Stainless Steel Equipment Material Requisition 4413-15C-2 Evaporators 3.1.29 7G-1 Weak Acid Pump 7G-1A Weak Acid Pump t

Drawings DS-7G-1 Data Sheet (Bechtel) 15G-3-13 Weak Acid Pump (Vendor) l 15G-3-54 Curve 7G-1 (Vendor) l 15G-3-55 Curve 7G-1A (Vendor)

Specifications 4413-A-1 General 4413-A-2 Equipment in Radioactive Areas 4413-G-1 Pump Specification 4413-X-1 Surface Preparation Material Requisition 4413-15G-3 Canned Pumps

DRAFT 2/80 3.1.30 7G-3 Hot Acid Pump Drawings DS-7G-1 Data Sheet (Bechtel)

~

15G-3-1 Hot Acid Pump (Vendor) 15G-3-57 Curve (Vendo')

r t

Specifications 4413-A-1 General 4413-A-2 Equipment in Radioactive Areas l

4413-G-1 Pump Specification 4413-X-1 Surface Preparation Material Reouisition 4413-15G-3 Canned Pumps 3.1.31 7C-2 Low Level Waste Evaporator Drawings DS-7C-2 DataSheet(Bechtel) 2A-16912 Separator (Vendor) 15C-2-5 Low Level Waste Evaporator (Vendor) 15C-2-21 3" Titanium Male Connector (Vendor) 15C-2-22 4" Titanium tiale Connector (Vendor) 15C-2-23 Welding Procedure Titanium (Vendor) 15C-2-27 Coils & Coil Supports (Vendor) 15C-2-55 Welding Qualification (Vendor) 15C-2-56 Procedure Qualification (Vendor) 15C-2-58 Welding Instructions (Vendor) 15C-2-59 Welding Instructions (Vendor) 15C-2-60 DrawingIndex(Vendor) 15C-2-61 Air Sparger Details (Vendor) 15C-2-63 Bent Tube Mark C (Vendor) 15C-2-64 Bent Tube Mark E (Vendor) i 15C-2-65 Bent Tube fiark F (Vendor) 15C-2-66 Bent Tube Mark G (Vendor) 15C-2-67 Pad & Flange for Coil (Vendor) 15C-2-68 Pad & Flange for Coil (Vendor) 15C-2-104 Bent Tubes for Nozzle G (Vendor) i 15C-2-105 tkzzle fiark J (Vendor) 15C-2-114 Bottom Trunnion Detail (Vendor) 15C-2-115 Top Trunnion Detail (Vendor) 15C-2-123 Attaching Conn. to Vessels (Vendor) 15C-2-125 Special Stud and Nut (Vendor) 15C-2-126 Remote Removable Eductor (Vendor) 15C-2-129 General Shop Procedure (Vendor) i 15C-2-130 Balancing Procedure (Vendor) 15C-2-133 Overall Dimensions Remote Eductor (Vendor) 15C-2-134 Shipping Layout (Vendor) 15C-2-139 As Built Dimensions (Vendor) i

DRAFT 2/80 Specifications 4413-A-1 General 4413-C-1 Titanium Equipment 4413-C-2 Stainless Steel Equipment 4413-X-1 Surface Prenaration Material Reauisition 4413-15C-2 Evaporators 3.1.32 Vacuum Jets 7H-1 thru 7H-21, 711-23, 7H-24 Drawings 15H-1-2 EjectorSchedule(Vendor) 15H-1-3 Performance Curve (Vendor) 15H-1-4 Performance Curve (Vendor) 15H-1-5 Special Ejector Dimensions (Vendor) 15H-1-6 Special Ejectors (Vendor) 15H-1-8 Ejector Schedule (Vendor)

Specifications

(

Included in Drawings Material Requisition t

4413-15H-1 Process Eductors 3.2 NFS Equioment 3.2.1 70-15 Knockout Pot Drawing 7C-D-333 70-15 Knockout Pot (NFS) 3.2.2 7E-1 Acid Fractionator Feed Vaporizer Drawings DS-7E-1 Data Sheet (NFS) 7E-E-361 7E-1 Shell Replacement (NFS) 70-L-392 Piping Details for 7E-1 Replacement (NFS) 3.2.3 YS-967B York Separator i

Drawings SC-2181-2 York Vertical Separator (Vendor) 70-L-601 Separator Between 7C-3 & 7E-1 (NFS)

DRAFT 2/80

< 3.2.4 7H-25 Fractionator Bottoms Jet 7H-26 Vaporizer Bottoms det The original pumps on the fractionator and the vaporizer were replaced with jets ordered to the following specifications:

Modified Model 1A Penberthy steam jet ejector, S/N 54833-030, all 316 SS construction 1/2" screwed inlet and outlet 3/8" steam inlet. To be sized for a flow of 1.0 gal / min with a suction lift of 1.8 ft and a discharge head of 77 feet of water.

Std. Penberthy Model lA steam jet ejector, all stainless steel 316 construction,1/2" screwed inlet and outlet, 3/8" screwed steam inlet.

Drawinos 7P-240 7H-26 Jet for 7G-10 Replacement (NFS) 7C-L-408 7H-25 Jet for 7G-5 Replacement (NFS) 3.3 General Drawings 70-P-409 7C-5 to 7C-2 Crossover (NFS) 70- -410 Steam Supply to 7H-25 & 7H-26 (NFS) l 70-P-411 Steam Supply to 7H-25 & 7H-26 (NFS) 7D-P2412 Steam Supply to 7H-25 & 7H-26 (NFS) 70-P-413 Steam Supply to 7H-25 & 7H-26 (NFS) 70-P-414 7C-3 to 7H-25 Jet (NFS) 70-L-456 7C-2 Cooling Water Condensate (NFS) 70-L-531 70-3 to 70-10 Jet (NFS) 70-L-603 7H-26 Relocation (NFS) 70-L-606 7E-12 Installation Replacement (NFS)

I i

l

MEETING WITH NRC, NFS, NYSERDA ON D&D INFORMATION - February 2,1980 Participants Organization CJHaughney NRC--FCAF N. J. Newman NFS J. P. Duckworth NFS A. T. Clark, Jr.

NRC--FCAF R. L. Black NRC--ELD L. C. Rouse NRC--FCAF t

Observers:

J. A. Turi DOE W. N. Crofford EPA e

i i

I 5