Text
- - - _ _ _
e-p
~
Firm NRC418 U.S. NUCLEAR REGULATORY COMMISSION l
('
CERTIFICATE'OF COMPLIANCE 10 C R 71 For Radioactive Materials Packages 1.bl Certificate IJumber 1.(b) Revision No.
1.(c) Package Identification No.
1.(d) Pages No. 1.(e) Total No. Pages 9089 2
USA /9089/A 1
2
- 2. PREAMBLE 2 (a) This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10s and 146-19-100 of the Department of
' Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packaging and contents described in item 5 below, met s the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations, Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.**
2.tc)
This arrtificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the pe.:kage will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)
Prepared by (Name and address):
3.(b)
Title and identification of report or application:
Hittman Nuclear & Development Hittman Nuclear & Development Corp.
Corporation application dated April 6,1977.
-9190 Red Branch Road Columbia, Maryland 21045 3.r ) Docket No. 71-9089 e
- 4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
- 5. Description of Packagig and Authorized Contents, Model Number, Fissile Class, Oter Conditions, and
References:
(a)
Packaging (1) Model No.: HN-100S (2) Description The cask is a steel annulus 84-1/4 inches high by 81-5/8 inches in diameter. The cavity is 74-1/2 inches high by 75-5/8 inches
.in diameter. The side walls consist of two plys of 1-1/2-inch steel.
The 3-inch steel base is integrally welded to the cylinder.
The lid is a-3-inch steel plate, stepped to mate with the upper flange of the cylinder. A centrally located shield plug is similarly constructed.
The lid and plug are attached with stud-bolts and nuts and sealed with Buna N 0-ring gaskets. A plugged drain line is provided.
Four skewed lugs welded to the outer shell are used for tie down.
Three lugs welded to the outer shell are used for cask lifting.
The lid and plug have three and' one shackles, respectively, for lifting.
The package gross
~
weight is approximately 43,000 pounds.
(3) Drawings The packaging is fabricated in accordance with PX Enoineering L
Company, Inc., Drawing No.: 449-A, Sheet 1, Rev. 0; Sheet 2, Rev.1; Sheet -3, Rev.1; and Sheet 4, Rev. 0; and C001-5-9121, Sheet 1, Rev. 1.
l l
800.4080112
Page 2 - Certificate No. 9089 - Revision No. 2 - Docket No. 71-9089 5.
(b) Contents (1) Type and form of material.
Process solids, either dewatered, solid or solidified, meeting the requirements for low specific activity radioactive material.
(2) Maximum quantity of material per package.
Greater than Type A quantities of radioactive material with the weignt of the contents, secondary containers,'and shoring not exceeding 17,000 pounds.
6.
Shoring shall be placed between the secondary containers und cask cavity to minimize movement during normal conditions of transport.
7.
The lid and shield plug lifting lugs shall not be used for lifting the enk, and
~
shall be covered in transit.
8.
The drain line shall be appropriately plugged and sealed prior to transport.
9.
Prior to each shipment, the packaging lid seals shall be inspected. The seals shall be replaced with new seals if inspection shows any defects or every twelve (12) months, whichever occurs first.
- 10. The package authorized by this certificate shall be transported on a motor vehicle, railroad car, aircraft, inland watercraft, or hold or deck of a seagoing vessel assigned for the sole use of the licensee.
'll.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
12.
Expiration date:
June 30, 1983.
REFERENCES Hittman Nuclear & Development Corporation application dated April 6,1977.
Supplements dated:
September 11, 1978; and March 17, 1980.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION dKA8
~
Charles E. MacDonald, Chief Transportation Certification Branch 1
Division of Fuel Cycle and Material Safety 00 Date*:
l-I l-