Notification of 800422 Meeting W/Review Group in Silver Spring,Md to Discuss Assessment of Thermal Hydraulic Technology of Transition Phase of Core Disruptive Accident in LMFBR, BNL-27366,informal Rept.Agenda Encl
ML19305C156
Person / Time
Issue date: 03/14/1980
From: Basdekas D
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
To: Curtis R, Wright R, Zuber N
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II), NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
References
NUDOCS 8003260073
Download: ML19305C156 (2)


Text

  • .S Q'A KICy

+

UNITED STATES 8

NUCLEAR REGULATORY COMMISSION

> y.,

g y

j W ASHINGT ON, D. C. 20555

\\

/

MAR 141980 MEMORANDUM FOR: Distribution FROM:

Demetrios L. Basdekas Experimental Fast Reactor Safety Research Branch

SUBJECT:

REVIEW GROUP MEETING ON ASSESSMENT OF THE THERMAL HYDRAULIC TECHNOLOGY OF THE TRANSITION PHASE OF A CORE-DISRUPTIVE ACCIDENT IN A LMFBR, BNL-HUREG-27366, INFORMAL REPORT.

A meeting will be held on April 22,1980,in Silver Spring, Maryland to review the state-of-technology of the subject matter. The Brookhaven National Laboratory has prepared an informal report on this subject.

A copy of this report will be sent to you under separate cover.

You are invited to comment on the BNL report, as well as offer your own additional information that you believe will be significant or helpful in further enhancing the completeness of it. The final report is planned for publication shortly after the meeting. ARSR considers the subject of transition phase phenomena, processes, and their interaction and potential sequences very important in LMFBR safety research and, in particular, in the development of the SIMMER Code. Hence, we consider an authoritative and & olete documentation of the state-of-technology in this area a necessary step toward their furtherance.

An agenda for the meetin is enclosed.

If you have any questions about it, call me at 427-4329 (FTS.

hnD LLLL Demetrios L. Basdekas Experimental Fast Reactor Safety Research Branch

Enclosure:

Agenda gges&9&73

AGENDA FOR REVIEW GROUP MEETING ON TRANSITION PHASE, BNL-NUREG-27366 WILLSTE BUILDING, ROOM 150 Silver Spring, Maryland April 22, 1980

'08:30 ARSR opening remarks Kelber, et al.

08:45 BNL presentation on transition Ginsberg/

phase state-of-technology Greene, BNL 10:15-Coffee Break-10:30 Los Alamos presentation Bell /Bohl 12:00 Lunch-01:00 Sandia presentation' J. Walker, et. al.

01:40 DOE /TMC/ANL presentation

~H.

Alter, et. al.

03:15 NRR Comments 03:30 Discussion - Conclusion All 05:30 Adjourn 4

I L

1

-w l

i ifpA 14 19fs?

DISTRIBUTION:

l Members of Review Group R.'Curtis, ARSR R. W. Wright, ARSR D.-Basdekas, ARSR N. Zuber, NRSR J. Meyer, NRR Invitees:

T. Murley, RSR C. Kelber, ARSR M. Silberberg N. Ganinill, NRR T. Speis, NRR L. Lois, NRR J. Scott, LASL C. Bell, LASL N. Bohl, LASL J. Walker, Sandia T. Theofanous R. Cerbone, BNL T. Ginsberg, BNL G. Greene, BNL R. Savio, ACRS H. Alter, DOE M. Kazimi, MIT A. Reynolds, UVA ARSR Staff WAENUb l

m,_u vve~vvw g)

_