References
NUDOCS 8003240018
Download: ML19305B926 (1)


Text

h UNITED STATES -

yoT).

p.; -

- NUCLEAR REGULATORY COMMISSION.

oceco##'l

.y

2

' WASHINGTHN, D. C. 20555 A,,k$&b

~

FEB 2s 1999

^

MEMORANDUM ~FOR:

Chairman Ahearne~

Comissioner Gilinsky Comissioner Kennedy Comissioner Hendrie Comissioner Bradford

.FROM:

James R. Shea, Diru for

~ Office of _' International. Pr6 grams THRU:.

Executive-Director for Operations (signedy r. A,nehm

SUBJECT:

USGS REVIEW 0F CHRISTOPHER NEWHALL'S PAPER Attached for' your infonnation, is USGS's quick review of Christopher Newhall's volcanologic analysis of Ebasco's work on the volcanology of the PNPP-1 site.

This review was performed in response to Mr. Chilk's February 5 Staff Require-ments Memo on the subject.

Jam

. Shea, Director-Off ce of International Programs

. Attachmen't: -

- USGS Review cc: dhilk, SECY J.Devine, OPE L.Bickwitt, OGC s

0 1

a 8

p';k /$m' l

  • $ Q b ' -Q Y is

).-

a i

9 8003240 C (7-

~

United: States Department of the Interior

~

c GEOLOGICAL SURVEY RESTON, VA. 22092 In Reply Refer To:

Mail Stop 905 February 22, 1980 Dr. Robert Jackson J

Chief, Geosciences Branch Division of Site Safety:a Environmental Analysis U.S. ' Nuclear Regulatory Commission Washington, D. C.

20555

~

Dear Bob:

Transmitted' herewith is our review of Christopher Newhall's " Review of Volcanologic Discussions in the PSAR and Related Documents, Philippine Nuclear Power Plant #1".

This review was prepared by Robert 1. Tilling, Chief, Office of Geochemistry and -Geophysics, U.S.G.S., with concurrence of Dr. Richard D. Krushensky, Acting Chief, Office of Environmental Geology, U.S.G.S.

Mr. Newhall is a

part-time employee-of the Geolo' ical Survey but his comments and our review of g

them have been developed independantly.

There have been no discussions of this subject between Drs. Tilling and Krushensky and Mr. Newhall.

I wish to reiterate here that the Survey has not reviewed the studies of

-Ebas'co nor have we studied the specific volcanic site-in question.

Our comments are based on Mr. Newhall's report and our expertise in volcanology in general.

l2 We have no objection to your making this review part of the public record.

Sincerely yours,

/C0M q

James F. Devine Deputy for Engineering Office of Earthquake Studies l

copy to: 'Newhall-DUPLICATE DOCUMENT f

Entire document previously entered into system underl.

i 9b0 b 0100Ti f

nNO No. of pages:

h7

[h

- - - - - - - - -