./f72

/

CERTIFICATE OF COT /.PLlANCE

'f#"$)"

Fftr Radioactive Mastriats Packages

.s f

1.fal Certificate Number 1.(D) Revision No.

1.fe) Packaw identificxion No.

1.(d ) Pages No. 1.(e) Total No. Pages

.6400 4

USA /6400/B(

)F 1

5

[

PREAMBLE D ' 2.(a)

This certificate is issued to satisfy Sections 173..'.93a.173094.173.335. and 173.306 of the Department of Transportation Hazardous Materials ftequtat;cns (49 CFR 170139 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-143), as amended.

y 2.(b)

The packaging and contents described in item 5 below, rne'ats the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations. Part 71, ** Packaging of Radioactive Maternats for Transport and Transportation of Radioactive Material Under Certain Conditions."

2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicaole regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on t.$e basis of a safety analysis report of the packa;e design or application--

~

3.(a)

Prepared by (Name and adress):

3.(b)

Titfe and Mentification of report or application:

Westinghouse Electric Corporation Westinghouse Electric Corporation application P. O. Box 355 dated July 13, 1973, as supplemented.

Pittsburgh, Pennsylvania 15230 3.fc) Docket No.

71 6400 4, CONDITIONS 4

This certificate is conditional upon tne fulfilling of the requirernent.s of Subpart O of 10 CFR 71, as applicable, and the conditions specified in item 5 below.

5, Description of Packaging and Authorized Contents. Model Number, Fissile C: ass, other Conditions, and

References:

(a)

Packaging.

~

(

(1) Model No.: Super Tiger *

(2) Description A protective overpack which provides containmen't, impact resistance and thermal resistance for its contents.

The con-tainment vessel (cavity) is approximately 76" x 76" x 172" constructed of 3/16" thick and 10-gage mild steel.

Closure of the containment vessel is by a 1/4" thick aluminum plate with ! ilicone rubber gasket which is bolted to the containment vessel.

A pressure fitting with cap on the closure plate provides a means for leak testing.

The containment vessel is centered and supported in an outer 3/16" thick steel jac.ket by approximately 32" of polyurethane foam insulation at the end and 10" on the sides.

A removable section or cap con-sisting of approximately 34" of polyurethane foam insulation encased in steel with a silicone rubber gasket is bolted to the main outer steel jacket.

The overall dimensions of the packages are approximately 8' x 8' x 20'.

Vent holes are provided on the sides and ends of the container.

Set into each corner of the outer container are standard I.S.O. steel castings.

The total weight including weight of the contents is 45,000 pounds.

fs

(-

.A Super Tiger @ is a rdgistered trademark of Nuclear Engineering Company, Inc.