LT) f)%
'70 1257 e
( ERON NUCLEAR COMPANY,Inc.
RESEAR' H AND TECHNOLOGY CENTER 29% Ge.ge Wad 6ngton Way, Richland, Washington 99352 PHONE: (509) 375 7100 September 19, 1979 t'2 dd
~
,9..
- 1. :
t.
u.
y
, l 5.
v 9
Mr. W. T. Crow Q
Fuel Reprocessing and Fabrication Branch Division of Fuel Cycle and Material Safety U.S. Nuclear Regulatory Commission Washington, D.C.
20555
Dear Mr. Crow:
License No. SN'.1-1227 Docket No. 70-1257 A review of our files indicates the attached supplemental infor-mation regarding our planned laundry facility may be useful to your review of our application for license amendment dated August 27, 1979.
The equipment dimensions are given in Attachment 2.
The solid wastes accumulated in the filters will be monitored for uranium content and evaluated from a criticality control standpoint.
In addition, note that the solvent used is not an effective moderator (Cl CF.CC1F )*
2 2
Sincerely, b
W. S. Nechodom, Manager Licensing and Compliance WSN: sir Attachments M
~
80031903t6
- v y... e ' =' "
i AN AFFILIATE OF EXXON CORPOR ATION
J a.
O e
i ATTACIDIENT 1 SOLVENT DATA Lt l
i
/t
.1 q. a
_s _...... -
- {v
VALCLENE ONE 2600DR Accepted by 0.S.ll.A. as essentally similar to O. S. II. A. form 20 Aaland Chemical Co.,
Environmental
& Occupational Safety Dept. 11ox 2219, Coluubus, 0 11 43216 24-hour energency telephone: 606-324-1133 (located at Ashland, Kentucky)
Ashland product name:'Vallene one 260ddr licalth Physica Systems Inc.
05 52 4099030 2727 NW 43rd Street Data sheet no:
Gainesv111r., F1 32601 00180-002 latest revision:
07/78-78194 oduct:3990889 Invoice:248465 Attention: Purshasing/ Safety Dpt. Invoice date:
- 07/14/78 To: llealth Physics Systems Inc.
SECTION II HAZARDOUS COMPONENTS Ingredient Percent TLV Trichlorotrifluorethane 95%
100 ppm SECTION III PHYSICAL DATA Property Refinement Measurement initial boiling point for product 118.00deg f 47.77deg e 760.00mmhg Vabor pressure for product 33'4.00mmhg 71.00deg f 25.00deg c Vabor density for" product lie.t vi e r than air Specific gravity for prcduct Greater than water Percent volatiles for prcduct 100.00%
Evaporation rate
-(CCL4=1
=1)
.30
\\
\\
page one Appendix C
VALCLENE ONE 260PDR SECTION IV FIRE,AND EXPLOSION DATA CASil POINT (CLOSED CUP)
NOT APPLICABLE LOWER EXPLOSIVE LIMIT NOT APPLICABLE EXTINGUISilING MEDIA:
HAZARDOUS DECOMPOSITION PRODUCTS: !!AY FORM T0X IC MA CERIALS :,
HYDROGEN C ilL O R I D E, Pil0 S C EN E, llYDROGEli FLOURIDE, ETC.
SPECIAL FIREFIGilTING PROCEDURES: SELF-CONTAINED llREATilING APPAR-ATUS WITil A FULL FACEPIECE OPERATED IN PRESSURE-DEMAND OR OTIIER POSITIVE PRES'iU RE MODE.
UNUSUAL FIRE & EXPLOSION IIAZARDS:
NOT APPLICABLE SECTION V HEALTil llAZ ARD DAT A
[)
U
[
b TilRES110LD LIMIT VALUE:
1000 PPM EFFECTS OF OVEREXPOSURE: FOR PRODUCT EYES - CAN CAUSE SEVERE IRRITATION, REDNESS, TEARING, BLURRED VISION.
SKIN - CAN CAUSE SLIGilT IRRITATION.
BREATi!ING - EXCESSIVE IllllALATION OF VAPORS CAN CAU SE !! ASAL AND RESPI!!ATORY I R RIT AT IO!!, DIZZINESS, WEAKNESS, FAT-IGUE, NAUSEA, llE A D A Cll E, POSSIBLE UNCONSCIOUSNESS, AND EVEN ASPilYXIATION.
SWALLOWING - CAN CAUSE GASTROINTESTINAL IRRITATION, NAUSEA, V0HITIt!G, DIARRHEA.
IF ON SRIN:
110ROUCllLY UASit EXPOSED AREA WITil SOAP AND UATER.
RE!!OVE CONTA!!IN A".'ED CLOTl!ING.
LAUNDER CONTAMINATED C LOT 111NG IlEFORE RE-USE.
IF IN EYES:
Fl.U S!! UITil LARGE AMOUNTS OF WATER, 1.1FTING UPPER AND I.0UER L1DS OCCASlotiALLY, GET !!EDICAL ATTENTION.
IF SWALLOUED:
GIVE TWO GLASSES OF UATER; I N D U C E V 0 :l I T Ill G IMl!EDIATELY llY STICRING FINGER DOWN TilROAT.
CALL A PilYSICIAN.
NEVER GIVE ANYTilING BY MOUTil TO AN UNCON-SCIOUS PERSON.
IF liREATilED:
IF AFFECTED, RE!!OVE INDIVIDUAL TO FRESil AIR.
IF BREAT!!1NG IS DIFFICULT, ADMINISTER OXYGEN.
IF
BREATillllG llAS STOPPED GIVE ARTIFICIAL RESPIRATI0tl.
KEEP PERS0!i UARM, QUEIT AND GET MEDIC /.L ATTENTION.
DO NOT GIVE STIMULANTS.
EPINEPHRINE OR EPl!EDRINE tiAY ADVERSELY AFFECT Tile IIEART WITil FATAL RESULTS.
SECTION VI REACTIVITY DATA o
HAZARDCUS PO LYMERIZ ATIO!i:
CANNOT OCCUR STABILITY: STABLE INCOMPATABILITY:
AVOID C011 TACT WIT!!.:, ALKALI METALS, PO.WDER-ED METALS, ALKALINE METALS SECTION VII SPILL OR LEAK PROCEDURES STEPS TO BE'TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED:
SMALL SPILL:
ALLOW TO EVAPORATE.
VENTILATE AREA.
LARGE SPILL:
ELIMINATE ALL IC111 TION SOURCES (FLARES, FLA!!ES
~
I!1CLUDING PILOI LICitT S, ELECTRICAL SPARKS).
PERSONS NOT WEARING PROTECTIVE EQUIPMENT Sl!OU LD BE EXCLUDED FROM AREA 0F SPILL UNTIL CLEAti-UP 11AS BEEN COMPLETED.
PR' VENT STOP SPILL AT SOURCE, DIKE AREA 0F SPILL TO E
S PRE ADIllG, PUMP LIQUID TO SALVAGE TANK.
REMAINING LIQ-UID MAY BE TAKEN UP ON SAND, CLAY, EARTil, FLOOR ABSOR-BENT, OR OTilER ABSORBENT MATERIAL AND Si!0VELED INTO CONTAltIERS.
ALLOW TO EVAPORATE.
PERSONS NOT WEARING PROTECTIVE EQUIPMENT S110U LD BE EXCLUDED FROM AREA UN-TIL LEnK llAS BEEN REPAIRED.
LARGE SPILL:
MATERIAL COLLECTED ON nBSORDENT MATERIAL MAY BE DEPOSITED IN A POSTED T0XIC SUBSTANCE LANDFILL IN ACCORDANCE WITil LOCAL, STATE, AND FEDERAL REGULATIONS, DESTROY BY INCINERATI0tt WITH OFF GAS SCRUBBER.
SECT 10tl VIII P140TECTIVE EQUIPMENT TO DE USED RESPIRATORY PROTECTION-IF TLV 0F T!!E PRODUCT OR ANY COMPON-i ENT IS EXCEEDED, A NIOSH/ MESA JOINTLY APPI:0VED SELF-CONTAINED BREATilI!1G APPARATUS WITil A FULL FACE PIECE OPERATED IN PRESSURE DEMAND OR OTilER POSITIVE PRESSURE MODE IS ADVISED; !!0W EV E R, OS!!A REGULATIONS ALSO PERMIT OT!!ER NIOSil/ MESA RESPIRATORS UtIDER SPECIle1ED CONDIT-IONS.
(SEE YOUR SAFETY EQUIPMENT SUPPLIER).
l 4
~
PROVIDE SUFFICIENT MECHAllICAL (GENERAL) AND/OR VEllTIL ATI0ll:
BELOW
. LOCAL EXHAUST VENTILATION TO MAltlTAIN EXPOSURE TLV(S).
PROTECTIVE CLOVES:
WEAR RESISTANT CLOVES SUCil AS: POLYVINYL ALC0110L EYE PROTECTION:
CllEMICAL SPLASH GOCCLES Ill COMPLIAllCE WITH HOWEVER, OSilA REGULA-OSilA REGULATIO!!S ARE ADVISED, CLASSES.
(SEE TIONS ALSO PERMIT OTilER TYPE SAFETY YOUR SAFETY EQUIPMENT SUPPLIER).
NORMAL WORK CLOTIIING COVERING OTHER PROTECTIVE EQUIPME11T:
ARMS AN) LECS.
SECTION IX SPECIAL PRECAUTIONS OR OTHER COMMENTS CONTAINERS OF THIS MATERIAL MAY BE IIAZARDOUS WilEN EMPT SINCE EMPTIED CONT AIllERS RETAIN PRODUCT RESIDUES (VAPOR, LIQUID, AND/OR SOLID), ALL IIAZ ARD PRECAUTIOliS CIVEN IN THIS DATA SilEET MUST BE OBSERVED.
ACCUMULATED llEREll! IS BELIEVED TO BE ACCUR-Tile INFORMATI0Il IS 110T WARRANTED TO llE UllETllER ORIGINATING WITil ATE BUT IN RECIPIENTS ARE ADVISED TO C0!! FIRM
.ASHLAND OR NOT.
ADVANCE OF NEED TilAT THE INFORMATION IS CURRENT, APPLI-AND SUITABLE TO THEIR CIRCUMSTANCES.
- CABLE, l
.