ML19305B030

From kanterella
Jump to navigation Jump to search
Forwards Final Deficiency Rept Re Inadequate Vendor QA Program
ML19305B030
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 01/04/1980
From: Eric Turner
HOUSTON LIGHTING & POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19305B031 List:
References
ST-HL-AE-403, NUDOCS 8003190053
Download: ML19305B030 (2)


Text

_ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _

Houston 7Tc -

8e r Com3any January 4, 1980 Electnc Tower ST-HL-AE-403 l PO Box 1700 SFN: V-0540 f Houston. Texas 77001 Director, Region IV Office of Inspection & Enforcement 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 7610?

Dear Sir:

South Texas Project Units 1 & 2 Docket Nos. STN 50-498, STN 50-499 Final Report on the Reportable Deficiency Concernina Inadeouate Vendor Surveillance On December 4,1979, pursuant to 10 CFR 50.55(e), Houston Lighting and Power Company notified your office of a deficiency involving an apparent breakdown in the vendor surveillance program.

The attached final report provides a description of the deficiency, the actions taken to correct and prevent a recurrence of the deficiency, and a summary of the safety analysis. Further questions should be directed to Mr. D. G. Barker, Manager, South Texas Project at (713) 676-8891.

Very truly yours, C

. d .'/mm E. A. Turner Vice President Power Plant Constr"ction

& Technical Serv 1ces PLW:bf Attachment S 300a190 OSS

Houston bghting & Power Company ST-HL-AE-403 Page 2 .

cc: D. G. Barker A. J. Granger R. A. F-azar M. D. Schwarz (Baker & Botts)

R. Gordon Gooch (Baker & Botts)

J. R. Newman (Lowenstein, Newman, Reis, Axelrad & Toll)

Director, Office of Inspection & Enforcement Nuclear Regulatory Comission Washington, D.C. 20555 Charles Bechhoefer, Esquire Chairman, Atomic Safety & Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Dr. James C. Lamb, III 313 Woodhaven Road Chapel Hill, North Carolina 27514' Dr. Emeth A. Lue e Atomic Safety & Luensing Comission U.S. Nuclear Regulatory Comission -

Washington, D.C. 20555 Steven A. Sinkin, Esquire 116 Villita Street San Antonio, Texas 78205 Citizens for Equitable Utilities c/o Ms. Peggy Buchorn Route 1, Box 432 Brazoria, Texas 77422 ,

Richard W. Lowerre, Esquire Assistant Attorney General for the State of Texas P. O. Box 12548 Capitol Station Austin, Texas 78711 Henry J. McGurren, Esquire Hearing Attorney ,

Office of the Executive Legal Director U.S. Nuclear Regulatory Comission Washington, D.C. 20555 l

i l