Text

_ _ _ _ _

Houston 7Tc -

8e r

Com3any January 4, 1980 Electnc Tower ST-HL-AE-403 l

PO Box 1700 SFN: V-0540 f

Houston. Texas 77001 Director, Region IV Office of Inspection & Enforcement 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 7610?

Dear Sir:

South Texas Project Units 1 & 2 Docket Nos. STN 50-498, STN 50-499 Final Report on the Reportable Deficiency Concernina Inadeouate Vendor Surveillance On December 4,1979, pursuant to 10 CFR 50.55(e), Houston Lighting and Power Company notified your office of a deficiency involving an apparent breakdown in the vendor surveillance program.

The attached final report provides a description of the deficiency, the actions taken to correct and prevent a recurrence of the deficiency, and a summary of the safety analysis.

Further questions should be directed to Mr. D. G. Barker, Manager, South Texas Project at (713) 676-8891.

Very truly yours, C

. d.'/mm E. A. Turner Vice President Power Plant Constr"ction

& Technical Serv 1ces PLW:bf Attachment S

300a190 OSS

Houston bghting & Power Company ST-HL-AE-403 Page 2 cc:

D. G. Barker A. J. Granger R. A. F-azar M. D. Schwarz (Baker & Botts)

R. Gordon Gooch (Baker & Botts)

J. R. Newman (Lowenstein, Newman, Reis, Axelrad & Toll)

Director, Office of Inspection & Enforcement Nuclear Regulatory Comission Washington, D.C. 20555 Charles Bechhoefer, Esquire Chairman, Atomic Safety & Licensing Board U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Dr. James C. Lamb, III 313 Woodhaven Road Chapel Hill, North Carolina 27514' Dr. Emeth A. Lue e Atomic Safety & Luensing Comission U.S. Nuclear Regulatory Comission Washington, D.C. 20555 Steven A. Sinkin, Esquire 116 Villita Street San Antonio, Texas 78205 Citizens for Equitable Utilities c/o Ms. Peggy Buchorn Route 1, Box 432 Brazoria, Texas 77422 Richard W. Lowerre, Esquire Assistant Attorney General for the State of Texas P. O. Box 12548 Capitol Station Austin, Texas 78711 Henry J. McGurren, Esquire Hearing Attorney Office of the Executive Legal Director U.S. Nuclear Regulatory Comission Washington, D.C. 20555 l