T,. !,

TENNESSEE VALLEY AUTHORITY CHATTANOOGA, TENNESSEE 374of 400 Chestnut Street Tower II March 13, 1980 Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region II - Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Dear Mr. O'Reilly:

HARTSVILLE NUCLEAR PLANT UNIT Al - REPORTABLE DEFICIENCY - RPV SHIELD WALL - WELD DEFICIENCIES (NCR HNP-A-087)

Initial report of the subject deficiency was made to R. W. Wright, NRC-0IE, Region II, on February 15, 1980. In coapliance with paragraph 50.55(e) of 10 CrR Part 50, we are enclosing the first interim report of the subject deficiency. TVA anticipates transmitting the final report on or before May 30, 1980. If you have any questions regarding this matter, please call Jim Domer at FTS 854-2014.

Ve y truly yours, TENNESSEE VALLEY AUTHORITY

& f jL. M. Mills, Manage,.

r" Nuclear Regulation and Safety Enclosure cc:

Mr. Victor Stello, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 8008180 37 An Equal Opportunity Employer