ND-19-1304, ITAAC Closure Notification on Completion of ITAAC 2.2.03.08c.vi.03 (Index Number 191)

From kanterella
(Redirected from ML19304C160)
Jump to navigation Jump to search
ITAAC Closure Notification on Completion of ITAAC 2.2.03.08c.vi.03 (Index Number 191)
ML19304C160
Person / Time
Site: Vogtle 
Issue date: 10/31/2019
From: Yox M
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
ND-19-1304
Download: ML19304C160 (6)


Text

^

Southern Nuclear OCT 3 1 2019 Docket No.: 52-025 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Michael J. Yox Regulatory Affairs Director Vogtle 3 & 4 7825 River Road Waynesboro, GA 30830 706-848-6459 tel ND-19-1304 10 CFR 52.99(c)(1)

Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 ITAAC Closure Notification on Completion of ITAAC 2.2.03.08c.vi.03 [Index Number 1911 Ladies and Gentlemen:

In accordance with 10 CFR 52.99(c)(1), the purpose of this letter is to notify the Nuclear Regulatory Commission (NRC) of the completion of Vogtle Electric Generating Plant (VEGP) Unit 3 Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.2.03.08c.vi.03 [Index Number 191] for verifying the water volume of the In-containment Refueling Water Storage Tank (IRWST) is greater than or equal to 73,100 cubic feet. The closure process for this ITAAC is based on the guidance described in NEI 08-01, "Industry Guideline for the ITAAC Closure Process under 10 CFR Part 52," which was endorsed by the NRC in Regulatory Guide 1.215.

This letter contains no new NRC regulatory commitments. Southern Nuclear Operating Company (SNC) requests NRC staff confirmation of this determination and publication of the required notice in the Federal Register per 10 CFR 52.99.

If there are any questions, please contact Tom Petrak at 706-&48-1575.

Respectfully submitted, Mda.

Michael J. Yox'-

Regulatory Affairs Director Vogtle 3 & 4

Enclosure:

Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.2.03.08c.vi.03 [Index Number 191]

MJY/GCW/sfr

U.S. Nuclear Regulatory Commission ND-19-1304 Page 2 of 3 To:

Southern Nuclear Operating Company/ Georgia Power Company Mr. Peter P. Sena III (w/o enclosures)

Mr. D. L. McKlnney (w/o enclosures)

Mr. M. D. Meier (w/o enclosures)

Mr. D. H. Jones (w/o enclosures)

Mr. G. Chick Mr. M. Page Mr. M. J. Vox Mr. A. S. Parton Ms. K. A. Roberts Mr. T. G. Petrak Mr. C. T. Defnall Mr. C. E. Morrow Mr. J. L. Hughes Mr. S. Leighty Ms. A. C. Chamberlain Mr. J. C. Haswell Document Services RTYPE: VND.LI.L06 File AR.01.02.06 cc; Nuclear Reoulatorv Commission Mr. W. Jones (w/o enclosures)

Mr. F. D. Brown Mr. C. P. Patel Mr. G. J. Khouri Ms. S. E. Temple Mr. N. D. Karlovich Mr. A. Lerch Mr. C. J. Even Mr. B. J. Kemker Ms. N. C. Coovert Mr. C. Welch Mr. J. Gaslevic Mr. V. Hall Mr. G. Armstrong Ms. T. Lamb Mr. M. Webb Mr. T. Fredette Mr. C. Weber Mr. S. Smith Qqiethorpe Power Corporation Mr. R. B. Brinkman Mr. E. Rasmussen

U.S. Nuclear Regulatory Commission ND-19-1304 Page 3 of 3 Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. S. M. Jackson Dalton Utilities Mr. T. Bundros Westinqhouse Electric Company. LLC Dr. L. Oriani (w/o enclosures)

Mr. D. C. Durham (w/o enclosures)

Mr. M. M. Corletti Ms. L. G. Iller Mr. Z. 8. Harper Mr. J. L. Coward Other Mr. J. E. Hosier, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., GDS Associates, Inc.

Mr. 8. Roetger, Georgia Public Service Commission Ms. 8. W. Kernizan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. 8. Blanton, Balch Bingham

U.S. Nuclear Regulatory Commission ND-19-1304 Enclosure Page 1 of 3 Southern Nuclear Operating Company ND-19-1304 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.2.03.08c.vl.03 [Index Number 191]

U.S. Nuclear Regulatory Commission ND-19-1304 Enclosure Page 2 of 3 ITAAC Statement Desion Commitment 8.c) The PXS provides RCS makeup, boration, and safety injection during design basis events.

Inspections. Tests. Analvses vi) Inspections of each of the following tanks will be conducted:

3.- IRWST Acceptance Criteria vi) The calculated volume of each of the following tanks is as follows:

3. IRWST > 73,100 ft^

between the tank outlet connection and the tank overflow ITAAC Determination Basis Multiple ITAAC are performed to demonstrate that the Passive Core Cooling System (PXS) provides Reactor Coolant System (RCS) makeup, boration, and safety injection during design basis events. This ITAAC performs an inspection to verify the volume of the In-containment Refueling Water Storage Tank (IRWST) between the tank outlet connection and the tank overflow is greater than or equal to 73,100 ft^.

An inspection was performed of measurements made inside the IRWST. A laser scanner was used to determine the inside volume between the tank outlet connection and the tank overflow.

Various scanner locations were used within the tank to provide a complete scanned coverage of the internal surface of the IRWST. One complete data file consisting of the composite of the scans which represents the entire internal surface of the IRWST was analyzed. Significant permanent features that displace the useable tank volume such as the passive residual heat removal heat exchanger, the integrated head package stand, and the automatic depressurization system spargers, were represented in the scanned volume and mathematically removed from the IRWST useable volume. Smaller permanent features such as ladders were conservatively accounted for from the design calculation and also removed from the useable volume.

Measurements were taken using survey equipment in accordance with 26139-000-4MP-T81C-N3201, "Construction Survey" (Reference 1). The calculated volume of the IRWST represented by the 3-D model developed from the scanned data between the tank outlet connection and the tank overflow was determined to be 74,412 ft^ which meets the minimum volume of 73,100 ft-specified in the ITAAC Acceptance Criteria. The results of the inspection are documented in the Principal Closure Document SV3-PXS-FSK-800191 (Reference 2) and is available for NRC inspection as part of the Unit 3 ITAAC completion package (Reference 3).

U.S. Nuclear Regulatory Commission ND-19-1304 Enclosure Page 3 of 3 ITAAC Finding Review In accordance with plant procedures for ITAAC completion, Southern Nuclear Operating Company (SNC) performed a review of all ITAAC findings pertaining to the subject ITAAC and associated corrective actions. This review found that there are no relevant ITAAC findings associated with this ITAAC. The ITAAC completion review is documented in the ITAAC Completion Package for ITAAC 2.2.03.08c.vi.03 (Reference 3) and is available for NRC review.

ITAAC Completion Statement Based on the above information, SNC hereby notifies the NRC that ITAAC 2.2.03.08c.vi.03 was performed for VEGP Unit 3 and that the prescribed acceptance criteria were met.

Systems, structures, and components verified as part of this ITAAC are being maintained in their as-designed, ITAAC compliant condition in accordance with approved plant programs and procedures.

References (available for NRC Inspection)

1. 26139-000-4MP-T81C-N3201, Rev. 5, "Construction Survey"
2. SV3-PXS-FSK-800191, Rev. 0, "ITAAC Verification Volume of the IRWST'
3. 2.2.03.08c.vi.03-U3-CP-Rev0, ITAAC Completion Package