From:
Domke, Matthew To:
"dean.walker@exeloncorp.com" Cc:
"Cruz, Ramon:(Exelon Nuclear)"
Subject:
D2R26 NRC ISI RFI part B Date:
Wednesday, October 23, 2019 9:31:34 AM Good morning DJ, After review of the outage schedule, Im planning for a Wed-Wed inspection, 10/30 -11/6.
Please adjust entrance and exit meetings accordingly.
Here are the additional items referenced by the initial request for information (ML19226A371), e.g. part B:
WO 4709411 WO 4668162 WO 1882842 WO 1882847 IRs (RFI, B.2):
IR 4071740 IR 4070767 IR 4074270 IR 4075547 NDE reports with relevant indications (RFI, B.3):
D2R25-UT-030 -I guess you provided all the associated NDE reports for component N20A-6 already. Please verify I have all NDE reports and associated corrective actions.
Thank you.
- Regards, Matt (630)829-9562 ADAMS Accession Number: ML19297G266