UNITED STATES NUCLEAR REGULATORY COMMISSION ADVISORY COMMITTEE ON REACTOR SAFEGUARDS WASHINGTON, DC 20555 - 0001 November 19, 2019 MEMORANDUM TO: Ho K. Nieh, Director Office of Nuclear Reactor Regulation FROM:

Scott W. Moore, Executive Director /RA/

Advisory Committee on Reactor Safeguards

SUBJECT:

ACRS REVIEW OF NUSCALE POWER, LLC, DESIGN CERTIFICATION APPLICATION - SAFETY EVALUATION WITH NO OPEN ITEMS FOR CHAPTERS 7, 10, 11, AND 17 During the 667th and 668th meeting of the Advisory Committee on Reactor Safeguards, September 3-5, 2019, and October 2-4, 2019, the Committee considered the staffs safety evaluation with no open items for Chapter 7, Instrumentation and Controls, Chapter 10, Steam and Power Conversion System, Chapter 11, Radioactive Waste Management, and Chapter 17, Quality Assurance and Reliability Assurance, of the NuScale design certification application.

The Committee reviewed and voted to accept recommendations from individual Members who were assigned as lead reviewers for each chapter. The Committee decided that no further briefing by the staff is needed to support the Committees review as it pertains to Chapters 7, 10 and 17 of the NuScale design certification application. To complete their Chapter 11 Phase 5 review, the Committee will review the staffs evaluation of the acceptability of NuScales realistic and design basis failed fuel fraction as part of its Source Term area of focus review. The Committee will inform the Commission of its finding in this matter relative to the requirements of 10 CFR 52.53 in a subsequent letter.

Attachments:

1. Chapter 7, Instrumentation and Controls (ML19297D108)
2. Chapter 10, Steam and Power Conversion System (ML19297D126)
3. Chapter 11, Radioactive Waste Management (ML19297D150)
4. Chapter 17, Quality Assurance and Reliability Assurance (ML19297D174)

References:

U. S. Nuclear Regulatory Commission, NuScale Power, LLC, Design Certification Application - Safety Evaluation With No Open Items for Chapter 7, Instrumentation and Controls, September 27, 2019 (ML19270F278)

U. S. Nuclear Regulatory Commission, NuScale Power, LLC, Design Certification Application - Safety Evaluation With No Open Items for Chapter 10, Steam and Power Conversion System, September 12, 2019 (ML19218A037)

U. S. Nuclear Regulatory Commission, NuScale Power, LLC, Design Certification Application - Safety Evaluation With No Open Items for Chapter 11, Radioactive Waste Management, August 29, 2019 (ML19240A442)

U. S. Nuclear Regulatory Commission, NuScale Power, LLC, Design Certification Application - Safety Evaluation With No Open Items for Chapter 17, Quality Assurance and Reliability Assurance, August 8, 2019 (ML19207A371)

Advisory Committee on Reactor Safeguards, Proposed Focus Area Review Approach of the Advanced Safety Evaluation Report With No Open Items for the Design Certification Application of the NuScale Small Modular Reactor, September 25, 2019 (ML19269B682) cc: A. Bradford, NRR S. Lee, NRR M. Dudek, NRR O. Tabatabai, NRR G. Tesfaye, NRR November 19, 2019

SUBJECT:

ACRS REVIEW OF NUSCALE POWER, LLC, DESIGN CERTIFICATION APPLICATION - SAFETY EVALUATION WITH NO OPEN ITEMS FOR CHAPTERS 7, 10, 11, AND 17 Package No.: ML19297D008 Accession No: ML19297D065 Publicly Available Y Sensitive N Viewing Rights:

NRC Users or ACRS Only or See Restricted distribution *via email OFFICE ACRS/TSB SUNSI Review ACRS/TSB ACRS NAME MSnodderly MSnodderly LBurkhart SMoore DATE 10/24/2019 10/24/2019 11/12/2019 11/19/2019 OFFICIAL RECORD COPY