ML19296D760

From kanterella
Jump to navigation Jump to search
Requests Approval of Proposals to Defer Annual Radiation Emergency Drill to 800207 & to Perform mini-drills to Improve Health Physics Practices.Radiation Emergency Drill Will Be Performed Before 800331
ML19296D760
Person / Time
Site: Crane 
Issue date: 01/30/1980
From: Wilson R
METROPOLITAN EDISON CO.
To: Jay Collins
NRC - TMI-2 OPERATIONS/SUPPORT TASK FORCE
References
TLL-035, TLL-35, NUDOCS 8003130124
Download: ML19296D760 (2)


Text

.

g wrk,i mm.m c ggpi

=uau w......

Metropolit.in Edison Cornpany me-I f

Past Of fice iku 480 b

Mntiletown, Pennsylvania 1/057 717 944 4041 hter's Direct D.at Number January 3n 1980 TLL 035 TMI Support Attn:

J. T. Collins, Deputy Director U. S. Nuclear Regulatory Commission c/o Three Mile Island Nuclear Station Middletown, Pa.

17057

Dear Sir:

Three Mile Island Nuclear Station, Unit II (TMI-2)

Operating License No. DPR-73 Docket No. 50-320 Annual Emergency Radiation Drill In your letter of December 28, 1979, you granted a waiver of the 1979 Annual Emergency Drill until January 31, 1980.

To date, seven (7) Radiological Emergency Drills were performed which involved the coordinated response of the Unit II Emergency Organization consistent with the existing Emergency Plan.

The scenarios for these drills were as follows:

DATE SCENARIO January 16 RCBT Rupture January 17 Makeup System Valve Packing Leak January 18 Dropped Epicor II Demineralizer Liner January 23 Fire at Interim Waste Storage Building January 24 Failed Open R. B. Purge Valve (s)

January 25 DH-V6B Gross Packing Leak January 28 Dropped Epicor II Demineralizer Liner In assessing the overall response, it was considered that except for the January 18 drill (which was rerun on January 28), the Emergency Organization response was such that the postulated accident was controlled, its consequences mitigated and personnel safety ensured to a satisfactory level. However, it is recognized that some cmergency practice problems still exist which require our continued training efforts and need to be resolved in order to improve the overall emergency response.

Action items have been assigned for this purpose.

It is felt that any further drills at this time will not show any significant change in the Emergency Organization's ability to effectively respond to accident situations, but rather the following program is proposed:

a.

Defer the drill presently scheduled for February 7, 1980.

800818o12J4 Metropol. tan Ed: son Company is a Member of the General Pubhc Utat.es System

~

o

, January 30, 1980 TLL 035 b.

Perform documented " mini-drills" at the :lP Supervisor and Tvchniclan level to improve the IIP practices characteristics of IIP organization emergency response.

c.

Perform a documented Radiation Emergency Drill prior to March 31, 1980, involving the combined organizational response.

Thereaf ter, quarterly drills will be patterned af ter the recent drills. Any unsatisfactory drill will be repeated in order to achieve a satis-factory performance.

Your consideration of the above proposal is requested.

neer ly, c

r-(~,

x-__

F. Wi son Director - TMI-II RFW:LWil: hah cc:

R. Vollmer R. Reid D. DiIanni B. Grier