ML19296D307
| ML19296D307 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 02/25/1980 |
| From: | Pilant J NEBRASKA PUBLIC POWER DISTRICT |
| To: | Ippolito T Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 8003030413 | |
| Download: ML19296D307 (1) | |
Text
LQA8000074 sdN GENERAL OFFICE P. O. 80 x.99. COLUMBUS, NEBR ASKA 68601
- x..,
Nebraska Publ.ic Power D. tr. t rete ~o~E i.on s....s.
is ic d
February 25, 1980 Director, Nuclear Reactor Regulation Attn:
Mr. Thomas A. Ippolito, Chief Operating Reactors Branch No. 3 Division of Operating Reactors U.S. Nuclear Regulatory Commission Washington, DC 20555
Subject:
Mark I Containment Program - General Electric h.gort NEDO-24583-1 " Structural Acceptance Criteria -
Plant Unique Analysis Application Guide" Cooper Nuclear Station NRC Docket No. 50-298, DPR-46
Dear Mr. Ippolito:
The subject report was transmitted to the NRC by the General Electri:
Company by letter from L. J. Sobon to D. G. Eisenhut dated December 27, 1979. This report provided information to ensure the structural accep-tance criteria are applied consistently in the plant unique structural evaluations performed as part of the Mark 1 Containment Program. Since this report will be utilized in support of the Cooper Nuclear Station containment evaluation program, we would like to request that the subject report be included on NRC Docket do. 50-298 for Cooper Nuclear Station.
Should you have any questions or comments relative to the above, please do not hesitate to contact me.
Sincerely yours, ilant o
Director of Licensing and Quality Assurance JDW/cmk
/)OW S
ll0 8003030 Y/3