ML19296C603

From kanterella
Jump to navigation Jump to search
C&C Irradiator Service, LLC, NRC Form 591 Part 1, Inspection Report 03039072/2019001
ML19296C603
Person / Time
Site: 03039072
Issue date: 10/17/2019
From: Jason Dykert
NRC Region 1
To: Nostrand C
C&C Irradiator Service
References
IR 2019001
Download: ML19296C603 (1)


See also: IR 07200201/1990001

Text

NRC FORM 591M PART 1

(07-2012)'

U.S. NUCLEAR REGULATORY COMMISSION

10 CFR 2.201

SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION

1. LICENSEE/LOCATION INSPECTED:

C&C lrradiator Service, LLC

1030 Evarts St, NE, Washington, DC 20018

Temporary Jobsite Inspection Location

190 East Bannock St, Boise, ID

REPORT NUMBER(S)

2019001

2. NRG/REGIONAL OFFICE

U.S. Nuclear Re,1ulatory Commission

Region I, 2100 R1enaissance Blvd, Suite 100

King of Prussia, Pennsylvania 19406-2713

3. DOCKET NUMBER(S)

030-39072

1

4. LICENSE NUMBER(S)

08-35447-01

1

5. DATE(S) OF INSPECTION

July 23 - 24, 2019, Oct. 17, 2019

LICENSEE:

The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Nuclear

Regulatory Commission (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of

procedures and representative records, interviews with personnel, and observations by the inspector. The inspection findings are as follows:

1. Based on the inspection findings, no violations were identified.

2. Previous violation(s) closed.

3. The violation(s), specifically described to you by the inspector as non-cited violations, are not being cited because they were self-

identified, non-repetitive, and corrective action was or is being taken, and the remaining criteria in the NRC Enforcement Policy, to

exercise discretion, were satisfied.

I 4.

Non-cited violation(s) were discussed involving the following requirement(s) and corrective action(s):

During this inspection, certain of your activities, as described below and/or attached, were in violation of NRC requirements and are being

cited in accordance with the NRC Enforcement Policy. This form is a NOTICE OF VIOU1TION, which may be subject to posting in

accordance with 10 CFR 19.11. (Violations and Corrective Actions)

Statement of Corrective Actions

I hereby state that, within 30 days, the actions described by me to the Inspector will be taken to correct the violations identified. This statement of

corrective actions is made in accordance with the requirements of 10 CFR 2.201 (corrective steps already taken, corrective steps which will be taken,

date when full compliance will be achieved). I understand that no further written response to NRC will be required, unless specifically requested.

Title

LICENSEE'S REPRESENTATIVE

NRCINSPECTOR

BRANCH CHIEF

Printed Name

Jason Dykert, Principal Inspector

Michael Reichard, Region I Reviewer

Anne DeFrancisco

Signature

Date

  • NRC FORM 591M PART 1 (07-2012) (RI Rev. 09/12/2013) G:\\WBL Documents\\WBL Inspection Records\\R08-35447-01.2019001.591M Part 1.doc

SUNSI Review Completed By:

IRA/

Jonathan Pfingsten

0 Public 0 Non-Sensitive

This document becomes an NRC Official Agency Record once it is signed l:ly the Branch Chief