ML19296C378

From kanterella
Jump to navigation Jump to search
Forwards Update to Final Deficiency Rept Re Incorrect Valve Weight Used in Piping Analysis
ML19296C378
Person / Time
Site: Sequoyah  
Issue date: 02/11/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19296C379 List:
References
NUDOCS 8002250727
Download: ML19296C378 (1)


Text

i' TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 37401 400 Chestnut Street Tower II February 11, 1980 Mr. James P. O'Reilly, Director Office of Ins ction and Enforcement U.S. Nuclear Rs. ulatory Commission hagion II - Suit 3100 lul Marietta Stree.

Atlanta, Georgia 3 03

Dear tir. O'Reilly:

SEQUOYAH NUCLEAR PLAh"I UNITS 1 AND 2 - VALVE WEIGHT USED IN PIPING ANALYSIS IS INCURRECT - NCR Chu 80 ADDITIONAL INFORMATION The subject deficiency was initially reported to NRC-0IE Inspector W. T. Cottle on January 4,1980, in accordance with 10 CFR 50.55(e).

A final report was submitted on February 4, 1980.

Enclosed is additional information providing justification for allow-ing fuel loading in unit 1 before conpletion of the corrective action for this deficiency. The corrective action vill be completed before initial crici aliey.

If you have any questions concerning this matter, please get in touch with D. L. Lambert at FTS 854-2581.

Very truly yours, TENNESSEL VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety En:losure j

cc:

Mr. Victor Stello, Jr., Director (Enclosure) /

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 30/7 ss

///

An Equal Opportunity Employer

.