October 24, 2019 MEMORANDUM TO:

Christopher M. Regan, Deputy Director Division of Fuel Management Office of Nuclear Material Safety and Safeguards FROM:

Nishka Devaser, Project Manager /RA/

Spent Fuel Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards

SUBJECT:

SUMMARY

OF SEPTEMBER 24, 2019, MEETING WITH DAHER-TLI TO DISCUSS PROPOSED AMENDMENTS TO THE VERSA-PAC TRANSPORTATION PACKAGE Purpose Daher-TLI (Daher) requested a pre-application meeting to provide to the U.S. Nuclear Regulatory Commission (NRC) staff an overview of two upcoming amendments to the Model No. Versa-Pac spent fuel transportation package.

Background

On September 24, 2019, an open meeting was held in Rockville, Maryland, at the request of Daher with the NRC staff to discuss Dahers upcoming amendments to the Versa-Pac transportation package. The list of meeting attendees, including those participating via telephone, is provided as an Enclosure.

The meeting was noticed on September 3, 2019 (see Agencywide Documents Access and Management System [ADAMS] Accession No. ML19246A074). The meeting attendance list is provided as an Enclosure, the presentation slides are in ADAMS at Accession No. ML19294A279.

CONTACT:

Nishka Devaser, NMSS/DFM (301) 415-5196

C. Regan 2

Discussion Daher-TLI is planning to submit two amendment requests for the Versa-Pac package Certificate of Compliance No. 9342 to support Centrus and X-energy with their pebble bed reactor project by adding TRISO fuel materials and 5A/B UF6 cylinders as allowable contents for the Versa-Pac.

The first amendment is to be submitted later this month and is a change in allowable contents.

The amendment will cover TRISO fuel related materials (TRISO particles, fuel compacts, etc.)

and will be limited to one additional criticality analysis to increase the fissile limit for the 20 weight percent enrichment band by limiting the acceptable hydrogenous packing materials.

The second amendment is planned for submittal in the late spring 2020 and will cover the 5A/B UF6 cylinder content (enrichment 20 weight percent). This amendment will add a new package variant: the VP-55XL. The design will be nearly identical to the VP-55; however, fabricated with a double height 55-gallon drum to increase the cavity height enough to fit a 5A/B cylinder. The amendment will include a significant revision to the safety analysis report with a licensing drawing for the new package, additional drop testing, and supplemental structural, thermal, and criticality analyses.

NRC staff had various questions regarding the criticality analysis of the first amendment to which Daher-TLI supplied answers. NRC staff had various questions regarding the structural layout of the second amendment to which Daher-TLI supplied answers.

Docket No.: 71-9342 EPID No.: L-2019-LRM-0062

Enclosure:

Meeting Attendees

C. Regan 3

SUBJECT:

SUMMARY

OF SEPTEMBER 24, 2019, MEETING WITH DAHER-TLI TO DISCUSS PROPOSED AMENDMENTS TO THE VERSA-PAC TRANSPORTATION PACKAGE DATED: October 24, 2019 DISTRIBUTION: D. Marcano ADAMS Memo Accession No.: ML19 OFFICE DSFM DSFM DSFM NAME NDevaser SFigueroa DDoyle DATE 10/16/19 10/16/19 10/24/19

Enclosure MEETING ATTENDEES Meeting

Title:

PRE-APPLICATION FOR MODEL NO. VERSA-PAC TRANSPORTATION PACKAGE

Participants:

Daher-TLI and the NRC Date:

September 24, 2019 Location:

U.S. NRC Headquarters, 0-8-B04 NAME AFFILIATION In attendance Andrew Barto NRC/NMSS/DSFM Nishka Devaser NRC/NMSS/DSFM Marty Karr Centrus Energy Charlie Murphy Daher-TLI Philip Sewell Daher-TLI Phone Attendees Andy Langston Daher-TLI Paul Balis Daher-TLI Antonio Rigato NRC/NMSS/DSFM