I 1 pa arc o
g UNITED STATES
. [ h,.- (f[ {
NUCLEAR REGULATORY COMMISSION
,.,) y~#: y REGION lV a
3, ' A ', /,Ug 611 RYAN PLAZA DRIVE, SUITE 1000
%,.....c AR LINGTON, TEX AS 76012
~ '
0 5 FEB G80 Docket No. 99900380/79-01 Struthers-Dunn, Incorporated Attn:
Mr. J. L. Pfeffer President Lambs Road Pitman, NJ 08071 Gentlemen:
Thank you for your letters of December 14, 1979 and January 11, 1980, in response to our letter dated November 21, 1979, with an enclosure.
The telephone conversation on January 31, 1980, between your Mr. F.
Merkel and our Mr. W. Foster clarified that only non-conforming material that has been dispositioned as "use-as-is" is presented to the customer.
We understand that there are no repair dispositions.
We have no further questions at this time. We will review your corrective action during a future inspection.
Sincerely, be*\\f' Uldis Potapovs, Chief Vendor Inspection Branch 8002210