e Fcim NRC418 U.S. NUCLE AR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE 10 R 71 For Radioactive Materials Packages e identificat on No.

1.(d)

N 1.(e) T tal No. Pages 1.(a) Certificate Number 1.(b) Hevision No.

1.(c)

Pack *d/9024/B PagI o.

E US 9024 3

2. PREAMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395. and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."

2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable reculatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a saf'ety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

St. Louis Testing Laboratories, Inc.

St. Louis Testing Laboratories, Inc. application 2810 Clark Avenue dated July 26, 1974, as supplemented.

St. Louis, M0 63103 3.(c)

Docket No.

71-9024

4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
5. Description of Packaging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and

References:

(a)

Packaging (1) Model No. :

STL-201 (2) Description A radiographic device contained within a steel drum and wood insulated overpack. Outer dimensions of the overpack are 11 inches in diameter by 14 inches high, conforming to Military Standard MS-27684-2.

The dimensions of the device are 4 inches by 5 inches by 9 inches in height. Main components of the device include a 1/8-inch stainless steel encasement shell, 30 pounds of depleted uranium shielding, solidified molten aluminum filler material, "S" shaped source tube, and shipping plug. The radiographic

~

device is centered and positioned within the steel drum by wood insulation.

The total weight of the package is approximately 60 pounds.

(3) Drawings The packaging is constructed'in accordance with the following St. Louis Testing Laboratories, Inc. Drawing Nos. :

STL-31A STL-282

/Ah STL-280 STL-283 STL-281 STL-201

/V/

and 80 022 io Military Standard MS-27684-2

'v Page 2

. Certificate No. 9024 - Revision No. 3 - Docket No. 71-9024 5.

(b) Contents (1) Type and form of material Iridium-192 as a sealed source which meets the requirements of special form as defined in 10 CFR 571.4(o).

(2) Maximum quantity of material per package 100 Curies of iridium-192 6.

The source assemblies authorized for use in radiographic device are limited to Model.

XC-305 as shown in (AECL) Atomic Energy of Canada Limited Drawing No. A4251-A-9, Model S-1 asshown in General Nuclear, Inc. Drawing No. B-107, and Nuclear Environ-mental Engineering, Inc. Model S-1 asshown in St. Louis Testing Laboratories Drawing No. STL-285-1.

7.

The nameplates shall be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining their legibility.

8.

Drum vent holes must be covered with durable weatherproof tape, or equivalent device.

9.

The package authorized by this certificate.is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

10.

Expiration date:

February 28, 1985.

REFERENCES St. Louis Testing. Laboratories, Ir.c. application dated July 26, 1974.

Supplenients dated: October 17, 1974; and January 9 and February 10, 1975.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION cALfd 0J Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and -

Material Safety FEB 0 5.1980 Date:

C

.