(NRC PUBUC DM'"'~'#

CHEM-NUCLEAR SYSJFfpFjNNC.

g h' ' ;

P.O. Box 1866 e Bellevue, Washingt -

e (206) 82fbh

,gE iv;0D' -

6 7

9 "A g g4 99 iB OCT.st i0 9

4 #,%3 %

1/

0 October 27, 1978

  • M Uk G;

p n-ggf;,, RCil0N A

(A Mr. Charles E. MacDonald, Chief Transportation Branch Division Of Fuel Cycle and Material Safety U.S. Nuclear Regulatory Commission Washington D.C. 20555

Subject:

Application for certificate of Compliance for CNSI Cask 18-450 (Big Bertha), NRC Docket No. 71-9122.

Gentlemen:

Pursuant to the requirements of Section 71.21 of 10 CFR 71, we are sub-mitting our application requesting authorization to deliver LSA Radio-active Material containing greater than Type A quantities of radioactive material to a carrier for transport in the CNSI Model No.18-450.

We have revised drawing 182-201 to show the location and heat treat of 125,000 PSI required for the cover tiedown bolts and clarification of the weld areas. To accomplish this Sheet 1 of 182-201 was revised (Rev. H) and Sheet 2 of 182-201 was reinstated (Rev. G).

Sheet 2 will show the necessary structural details.

Please replace Sheet 1, Rev. G of Drawing 182-201 with 182-201, Rev. H and add Sheet 2 of Drawing 182-201, Rev. G.

No change to the stress analysis is caused by these revisions.

If you have any questions regarding this matter please do not hesitate to contact me.

Sincerely, CHDI-NUCLEAR SYSTDIS, INC.

N n, 7,g 7,Y )

e

' rs ! -

.f-Karl H. Kinkade

.. ca-h n; L Manager Engineering

'\\

{

3 KHK/mm

Enclosures:

Drawing 182-201, Rev. H, Sheet 1 of 2 Drawing 182-201, Rev. G, Sheet 2 cc: Vince Stagliola, Boston Edison (w/o enclosures)

Ken Dufrane (w/o enclosures)

Bob Posik (w/o enclosures) ggg'/ gp')

Tom McCord (w/9 anclosures)

O U' h mme i

V O. ~ ~-

NO. OF PAGES

}

REASON O PAGE ILLEGIBLE.

O HARD COPY FILED AT.

PDR D OTHER

/

/

D BETTER COW REQUESTED ON E TOO LARGE TO FILM.

O HARD COW FILED AT:

PDR CF OTHER 94 ED ON APERTURE CARD NO.7f/ //670 W3M*