DISTRIBUTION:

-Central File QAB Projects QAB Chron. File

-.C 0 1 sc:0 ut

'~

VNoonan, DE JConway, CAB MEMORAtlDU'i FOR:

Richard D. Silver, Research & Standards Coordination Branch, Division of Safety Technology FROM:

Walter P. Haass, Chief, Quality Assurance Branch, Division of Engineering

SUBJECT:

REVIEW OF DRAFT ANSI STAf3DARDS - N45-N551.2, "STAilDARD FCR QUALIFICATION OF ASME CODE CLASS 2 & 3 PUMPS FOR SAFETY SYSTEM SERVICE" AND N551.5, " QUALIFICATION FOR TURBINE DRIVES" In accordance with your request dated November 14, 1980, we have evaluated the subject draft standards. Our connents are listed in the enclosure.

If there are any questions concerning these coments, please call Jin Conway on X27741.

Original signed by Walter P. Haass Walter P. Haass, Chief Quality Assurance Branch Division of Engineering

Enclosure:

As stated "c.

E 0

r_.

2. -

E a ::

E; Z

d:-.

c..

^:*

N M_

~

e

.e 8012150 qp ail g.._DE QAB.,

, _ D [,:J!f f,,.

L 390wAyAC9.... b.s s esse >

..s. - - -.

~

?mC FOGM 318 (9 76). 6 02 4

  • u*******"***""""*"**'""""'""'

Coments en Craf t ANSI 145-1551.2 1.

Page 36, Section 10.1, tnird line - Af ter " defined in" add "Section 3.1 of" and after 'N45.2.1" acc " Cleaning of Fluid Systens and Associated Conconents Curing Construction Phase of Nuclear Pcwer Plants."

2.

Page 36, Section 10.2, fourth line - Af ter "C of" add "Section 2.7 of ANSI."

2.

Page 37, Secticn 11.2 - Rewrite entire section as follows:

"The quality assurance and quality control requirements are established by the design specification. For pressure boundary parts, the manu-facturer as well as his suppliers shall follow the requirements of Sub-section NCA aCCO ' Quality Assur3nce' of Section III of the ASME Code.

Where acplicable, these recuirements should be supplemented by the QA requirements contained in ANSI N45.2 and the QA series daughter standards, e.g., N45.2.9, N45.2.ll, etc., and shall be followed for quality affecting activities covered by this standard."

Cannents an Draft 3NSI 1551.5 Page 6, Section 6.4.1, second line - Af ter " requirements of" delete " ANSI 145.2.2, Level C minicum," and add "Section 3.1.3 Class C of ANSI NJ5.2.1, Claaning of Fluid Systens and Associated Comconents During Construction Phase of luclear 3cwer Plants."

2.

Page 5, Section 6.4.2 - Rewrite this section to also include the activities of receiving, storage, and handling.

3.

P3ge 11, Section 3.1.2, fourtn line - Delete "Na5.2" and add "N45.2.9 ' Require-ments for Collection, Storage, and Maintenance of Quality Assurance Records for Nuclear Power Plants.

4 Page 11 - Add a Section 9 entitled ' Quality Assurance' with the following or similar statement:

" Quality affecting activities shall be in accordance witn tne QA requirements contained in ANSI N45.2 and the QA series daughter standards."