From: Holonich, Joseph To: "Shakun, Matthew A"; Odess-Gillett, Warren R Cc: Stattel, Richard; Morey, Dennis; Waters, Michael; Johnston, Jeanne; Morton, Wendell; Drake, Jason; Fields, Leslie; Harrison, Dana
Subject:
Draft Proprietary Safety Evaluation for WCAP-16096, Rev 4 Date: Tuesday, October 22, 2019 8:36:32 AM Matt/Warren, A copy of the draft safety evaluation (SE) for WCAP-16097, Revision 4, Common Qualified Platform Topical Report, has been placed in the box.com folder. You have previously been given access to the folder.
Based on its review of the information submitted by Westinghouse, the NRC staff finds the TR acceptable for referencing subject to the limitations specified in the topical report, and in the NRC staff SE. The draft SE is being provided for an accuracy, clarity, and proprietary information review.
Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), we have determined that the enclosed draft SE may contain proprietary information. If you believe that any information in the enclosure is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. Use brackets and yellow highlight to identify any
[proprietary information]. After 10 working days, the draft SE will be made publicly available, as appropriate, and an additional 10 working days are provided for you to comment on any factual errors or clarity concerns contained in the draft SE.
The final SE will be issued after making any necessary changes. The NRC staff's disposition of your comments on the draft SE will be discussed in the final SE.
When you respond, it must be via a letter from an authorized individual. Also, please provide an electronic Word file redline/strikeout version of the SE either via email or the box.com folder. Plus, provide in the formal transmittal and via a separate Word file, a table with the following columns; Comment No., Page and line Nos., Comment type (clarity, accuracy, proprietary), Suggested revision, and a blank column NRC Disposition.
Both this email and the draft SE have been placed in ADAMS and made Official Agency Records. The draft SE is declared as nonpublic because it may contain proprietary information. This email is declared public.
If you have any recommends or comments on the simplified SE process, we would be interested in receiving them. Please feel free to provide them in the formal letter or via an email to me. If you use email, the email would go in ADAMS as public.
If you have any questions, please feel free to contact me at 301-415-7297 or by email at jjh1@nrc.gov.
Joe Holonich, Sr. Project Manager U.S. Nuclear Regulatory Commission
Office of Nuclear Reactor Regulation 301-415-7297 This e-mail may contain proprietary information of the sending organization. Any unauthorized or improper disclosure, copying, distribution, or use of the contents of this e-mail and attached document(s) is prohibited. The information contained in this e-mail and attached document(s) is intended only for the personal and private use of the recipient(s) named above. If you have received this communication in error, please notify the sender immediately by email and delete the original e-mail and attached document(s).
This e-mail may contain proprietary information of the sending organization. Any unauthorized or improper disclosure, copying, distribution, or use of the contents of this e-mail and attached document(s) is prohibited. The information contained in this e-mail and attached document(s) is intended only for the personal and private use of the recipient(s) named above. If you have received this communication in error, please notify the sender immediately by email and delete the original e-mail and attached document(s).