Recommends Endorsement of NRC Analysis of the Effect of Natural Phenomena Upon Existing Pu Plants as NRC Position & Basis for Succeeding Increments of Analysis
ML19294C135
Person / Time
Site: 07000025
Issue date: 02/06/1980
From: Ayer J, Burkhardt W
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Rouse L
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
REF-PROJ-M-3 NUDOCS 8003070126
Download: ML19294C135 (1)


Text

' e na

]',

jo UNITED STATES L

U' g

y y

g NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 3'

E N,

/

~

FEB 6 1980 Docket No. 70-25 M-3 MEMORANDUM FOR: Leland C. Rouse, Chief Advanced Fuel and Spent Fuel Licensing Branch FROM:

J. E. Ayer/W. Burkhardt Advanced Fuel and Spent Fuel Licensing Branch

SUBJECT:

FEATURES OF ATOMICS INTERNATIONAL -

NUCLEAR MATERIAL DEVELOPMENT FACILITY AFFECTING SOURCE TERM The purpose of this memorandum is to recomend endorsement of the attached review as a staff position and a basis for succeeding increments of the analysis of the effects of natural phenomena upon existing' plutonium fabrication facilities. A draft of the subject report has been reviewed and comented upon by Dr. J. E. Carson, Argon'ne National Laboratory (ANL); Dr. R. P. Kennedy, Engineering Decision Analysis Corporation (EDAC); Prof. J.R. Mcdonald, Texas Tech University (TT); Dr. F. J. Tokarz, Lawrence Livermore Laboratory (LLL); Dr. W. J. Hall, University of Illinois; W. Burkhardt, NRC; and J. E. Ayer, NRC.

We recommend that this review including its summary and conclusions be adopted as a staff position subject to your approval. Subsequent to your approval we will make copies available tr, the public and to Atomics International in accordance with review and +cumentation procedures agreed upon and described in our February ad,1977 memorandum to R. M. Bernero.

(,ilES~

J. E. Ayer Advanced Fuel and Spent Fuel Licensing Branch Wr>ALA W. Burkhardt

[ Advanced Fuel and Spent Fuel Licensing Branch bd Approved by Leland C. Rouse, Chief Advanced Fuel and Spent Fuel Licensing Branch Division of Fuel Cycle and Material Safety

Enclosure:

" Identification of Features Within Pu Fabrication Facilities Whose Failure May Have a Significant Effect on the Source Term" 8008070 12 6

NRC ANALYSIS OF THE EFFECT OF NATURAL PHENOMENA UPON EXISTING PLUTONIUM PLANTS WORKING PAPER ON INCREMENT OF ANALYSIS -- Identification of Features Within Plutonium Fabrication Facilities Whose Failure May have a Signifi-cant Effect on the Source Term Features Observed in Atomics Inter--'ional - Nuclear Material Develop-ment Facility at Santa Susana, Ca

...sia 1.

Facility and Process Description The Atomics Inte national Nuclear Material Development Facility (NMDF) is situated in the Nuclear Cevelopment Field Laboratory (NDFL) located in the Simi Hills of Ventura County some 23 miles from Los Angeles.

The NMDF was most recently involved in the development of a plutonium and uranium mixed carbide,(Pu + V)-C, fuel.

Figure 1 is a plan view of the 055 Building (Plu-tonium Facility), which houses the NMDF. The (Pu + U)-C process flow is shown schematically in Figure 2.

Plutonium, in the form of Pu0 powder, is brought into the facility in 2

approved shipping containers and the inner containers removed in the open-faced hoods in room 124 (Analytical Lab). The inner containers are stored in the vault (room 131). All processing is performed in room 127 (NMDF) in gloveboxes most of which are "inerted". The glovebox arrangement is shown in Figure 3.

Gloveboxes #7, 9,11, and 12 are not used. The process operations per-formed in the gloveboxes are shown in Table I, Inventory at Risk.

Room air is suppliE via diffusers set in the Ceiling along the center-4 line of the NMDF (see F. '. 4). Air is exhausted via 2' x 2' HEPA filters near floor level along the east and west walls. The exhaust is drawn up via sheet metal risers to sheet metal ducts running along the east and west walls at ceiling level. Gases are exhausted from the gloveboxes via HEPA filters in the enclosures into ducts near the ceiling level over each glove-4 '

box line. The room and glovebox duc of the final HEPA filter bank (see F DUPLICATE DOCUMENT Entire document previously entered into system under:

hh h h ANO No. of pages:

.