ML19294B629

From kanterella
Jump to navigation Jump to search
IE Insp Rept 70-0820/79-11 on 790424-27.Noncompliance Noted: Central Alarm Sys & Maint of Personnel Search Device.Details Withheld (Ref 10CFR2.790)
ML19294B629
Person / Time
Site: Wood River Junction
Issue date: 10/16/1979
From: Bailey R, Devlin J, Shepherd R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML19294B617 List:
References
70-0820-79-11, 70-820-79-11, NUDOCS 8003050171
Download: ML19294B629 (1)


Text

'

U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION A."' ENFORCEMENT Regipn I Report No. 70-820/79-11 Docket No.70-820 Safeguards Group 1

License No.

SNM-777 Priority 1

Category UR-1 Licensee:

United Nuclear Corporation Fuel Recovery Operation Wood River Junction, Rhode Island Facility Name:

United Nuclear Corporation - FR0 Insoection at:

Wood River Junction, Rhode Island Inspection conducted:

April 24-27, 1979 terd

/o/4/M Inspectors:

c. ;

R. E. Shepherd, Physical Security Inspector date signed

'O / /

k I' b'L :.c h"iiibW l6f/6f7V j

R. J. Ba11ey,jPhysical Security Inspector date signed date signed Approved by:,iO

/

/

/T

. W. Devlin, Chief, Security and Investigation date signe'd Section, Safeguards Branch Inspection Summary:

Inspection on April 24-27, 1979 (Report No. 70-820/79-11)

Areas Inspected:

Routine, unannounced, physical protection inspection by regional based inspectors of the. licensee's implementation of the accepted Security Plan and 10 CFR 73.50,10 CFR 73.60, and 10 CFR 73.70 relative tr:

Physical Barriers; Access Controls; Keys, Locks, Combinations; Detection Aids; Central. Alarm and Cgmmunication System; Testing and Maintenance; SN'.

Protection; Records and Reports; Reports of Incidents. The inspection started during off-shif t hours'and involved 54 inspector-hours onsite by two NRC regional based inspectors.

Results: Of the nine areas inspected, no items of noncompliance were identified in seven areas.

Two items of noncompliance were identified in two areas (Infraction - central alarm system, Paragraph 7.a.; Infraction - maintenance of personnel search device, Paragraph 8.b.).

3003050 r.egion I rorn 12 (Rev. Acril 77)