ML19294B448

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-28 Re Namco Model EA180 Limit Switches.In Areas Where Ambient Temp Exceeds 175 F, Top Cover Gasket Will Be Replaced
ML19294B448
Person / Time
Site: Marble Hill
Issue date: 02/05/1980
From: Shields S
PSI ENERGY, INC. A/K/A PUBLIC SERVICE CO. OF INDIANA
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
IEB-79-28, NUDOCS 8002280401
Download: ML19294B448 (1)


Text

-

TC 1

i

-e

/

/

.J.

PUBLIC SERVICE INDIANA February 5,1930

s. w. sh,e u s Vice Pro 9 dant Electric Syvem Mr. James G. Keppler, Director Docket Nos.: STN 50-546 U. S. Nuclear Regulatory Commission STN 30-547 Region Ill Construction Permit Nos.:

799 Roosevelt Road CPPR-170 Glen Ellyn, IL 60137 CPPR-171 Marble Hill Nuclear Generating Station, Units 1 & 2 IE ">ulletin No. 79-23

Dear Mr. Keppler:

In response to IE Buitetin No. 79-23, Public Service Company of Indiana, Inc. (PSI) has determined that NAMCO Model EA180 limit switches are planned for use in safety-related equipment located both inside and outside the containment, including containment isolation valves, on the Marble H:ll Project.

PSI has reviewed the safety-related applications of NAMCO EAISO limit switches and has determined that some pieces of safety-relIted equipment use the subject limit switches date coded between 02-79 and 08-79. For that eqgipment which may be subject to a continuous ambient temperature of n: ore than 175 F, PSI will inspect tbc subject limit switches for the specified date code and replace the top cover gasket of the affected switches.

A non-conformance report will be initiated to track the affected limit switches and corrective action taken.

For equipment which has not been shipped to the site, vendors will replace all affected top cover gaskets. For affected limit switches that have been delivered to the site, corrective action will be completed af ter resumption of Safety Category I construc-tion.

Sincerely,

,/

i

/i S. W. Shields TDG:ebo cc:

U. S. Nuclear Regulatory Commission Of fice of Inspection and Enforcement Division of Reactor Operations Inspection ggQ Washington, D.C. 20555

%Ok E. R. Schweibinz, P.E.

J. J. Harrison 8002280 4d/

1000 East Mam Stmet. Plainfield, Indiana 461G8 317. 839 9611