Forwards Pittsburgh Testing Lab Repts 800985 & 800986, Rept of Potential Alkali Reactivity ASTM C-227 & C-289 for Gulf States Utils Co - S&W,Agent, for Fine & Coarse Aggregates,Respectively
ML19294B279
Person / Time
Site: River Bend 
Issue date: 12/31/1979
From: Weigand J
GULF STATES UTILITIES CO.
To: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19294B280 List:
References
RBG-7078, NUDOCS 8002280125
Download: ML19294B279 (1)


Text

-

e PQST OFPICE 5 OX 2951 8EAUM ON T, TExA S 77704 A R EA CODE 7 1 3 838 6631 Dec eber 31, 1979 PBG - 7078 File No. G9.5 Mr. Karl V. Seyfrit, Director U. S. Nuclear Regulatory Comtission Pegion IV 611 Ryan Plaza Drive Suite 1000 Arlington, TX 76011

Dear Mr. Seyfrit:

RIVER BEND STATICN UNIT 1 DOCKET NO. 50-458 As requested in your letter of December 13, 1979, enclosed are copies of Pittsburgh Testing Laboratory (PrL) Report numbers 800985 and 800986 for fine and coarse aggregates resp e lvely. Both reports show the two-month results of the ASTM G-227 nortar bar test being performed using low alkali (job canent) and Bayou Sara aggregates being used on the River Bend Project.

The 60-day results, reccrded as an average length change percent, are

+0.02 and +0.01 for fine ard coarse aggregates respectively and are well within the acceptance linits of +0.05 for 3-nonth and +0.1 for 6-nonth test durations.

The 3-nonth results are scheduled to be cmpleted on January 14, 1980.

We will transmit those results to you as soon as we receive then.

Sincerely, h$

  • =

J. G. Weigand General Manager-Nuclear ojects Enclosures 0002280 }K