ML19294B168
| ML19294B168 | |
| Person / Time | |
|---|---|
| Site: | 07105517 |
| Issue date: | 02/19/1980 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML19294B165 | List: |
| References | |
| NUDOCS 8002270383 | |
| Download: ML19294B168 (2) | |
Text
,
N k
I u
Form NRC418 U.S. NUCLE AR REGULATORY COMMISSION U
CERTIFICATE OF COMPLIANCE 10 CFR 71 For Radioactive Materials Packages 1.(a) Certificate NunTber 1.(b) Revision No.
1.(c) Package Identification No.
1 (d) Pages No. 1.(e) Total No. Pages Stil7 2
USA /5517/AF 1
2
- 2. PRE AMBLE 2.(a)
This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations, Part 71, Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."
2.(c)
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety ana!ysis report of the package design or application-3.(a)
Prepared by (Name and address):
3.(b)
Title and identification of report or applicawn:
Nuclear Fuel Services, Inc.
Westinghouse Electric Corporation application P.O. Box 218 dated December 15, 1967, as supplemented.
l Erwin, TN 37650 71-5517 3.(c)
Docket No.
- 4. CONOlTIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
- 5. Description of Packaging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and
References:
(a) Packaging:
(1) Model No.:
BB 250-1 (2)
Description:
A uranium dioxide powder shipping container, consisting of a steel cylinder held in the center of an outer container (two steel drums welded end-to-end) by fire-resistant foam.
Inner container is 11.5-inch ID,16-gage steel cylinder, 63.5 inches long, with bolted and gasketed top flange closure and seal welded bottom plate.
Inner container is centered and supported in a 22.5-inch ID by minimum 74-inch long,16-gage steel drum by fire resistant phenolic foam of AEC Material and Equipment Specification SP-9.
(3) Drawing:
The packaging is constructed in accordance with Westinghouse Electric Corporation Drawing No. C882D962 Sub. 5.
fN
>Y 0
I Page 2 - Certificate No. 5517 - Revision No. 2 - Docket No. 71-5517 5.
(b) Contents:
(1) Type and form of material:
2 or U 0 ) powder with a maximum density of 2 g U/cc Bulk uranium oxide (UO 38 end enriched to a maximum 4 w/o in the U-235 isotope.
The maximum H/U atomic ratio, considering all sources of hydrogenous material within the inner container shall not exceed 1.13.
(2) Maximum quantity of material per package:
Total contents not to exceed 250 pounds, with the U-235 content not to exceed four (4) kilograms.
(c) Fissile Class I
6.
Prior to each shipment, the lid gasket shall be inspected.
The gasket shall be replaced if inspection shows any defects or every twelve '(12) months, whichever occurs first.
7.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
6.
Expiration date: March 31, 1985.
REFERENCES Westingnouse Electric Corporation applicated dated December 15, 1967.
Supplement dated: January 18, 1968.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
& 54 Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:
.