l pe "ra uq(0, UNITED STATES
,e NUCLEAR REGULATORY COMMISSION y '; M g
> e, E
WASHINGTON D. C. 20555 3.' \\
. lO E
g, x&.....f JUL 2 71973 DOCKET NO.:
70-1257 APPLICANT:
Exxon Nuclear Company (Exxon)
FACILITIES: Uranium Fuel Fabrication Plant Richland, Washington
SUBJECT:
REVIEW 0F LICEllSE AMENDMENT APPLICATION DATED JUNE 20, 1979, TO REINSTATE AMErlDMENT NO. 9 (PROCESS OPERATIONS ON 10% EllRICHED FUEL RODS), PC NO. 79107A, MC REVIEWER:
R. L. Stevenson Backaround Amerd.ent No. 9 to SNM-1227, issued July 5,1977, authorized fabrication operations on a limited number of zirconium clad fuel rods containing uranium oxide at 10% enrichment, but the authorization expired December 31, 1977. The subject application requests reinstatement of Amendment No. 9 until December 31, 1979.
Discussion The safety basis for issuance of Amendment No. 9 was discussed in J. C. Delaney's review memorandum of July 5,1977.
Reinstatement of Amendment ilo. 9 would impose the same mass and spacing limits forming the basis for the scfety conclusion, which remains valid.
Conclusion Approval of the amendment application is recommended.
0.
WW Robert L. Stevenson Uranium Process Licensing Section Uranium Fuel Licensing Branch V
N Approved by:
W:
T'. Crow, Section Leader 8 0022 H
[
e