ML19294A888

From kanterella
Jump to navigation Jump to search
Forwards IE Circular 79-06, Failure to Use Syringe & Bottle Shields in Nuclear Medicine
ML19294A888
Person / Time
Issue date: 04/19/1979
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
OKLAHOMA, UNIV. OF, NORMAN, OK
References
NUDOCS 7905080126
Download: ML19294A888 (1)


Text

s

[pe atco,#'o UNITE D STATES h,s NUCLEAR REGULATORY COMMISSION Np 3

  1. 'e

^

REGION IV

$',[ ' f 611 RYAN PLAZA DRIVE, SUITE 1000

  • Tq AR LIN GTON, TE XAS 76011 0

w.-

,o April 19, 1979 License No.

35-03176-01 SS-IS I 74 - 01 M b University of Oklahoma Post Office Box 26901 Oklahoma City, Oklahoma Gentlemen:

The enclosed IE Circular 79-06 is forwarded to you for information.

If there are any questions related to your understanding of the suggested actions, please contact this office.

Sincerely,

.O f nd 3,.j, TfW

'Karl V. Seyfri Director

Enclosure:

1.

IE Circular No. 79-06 2.

List of IE Circulars Issued in Last 12 months

/SodeSoag

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Circular No. 79-06 April 19, 1979 FAILURE TO USE SYRINGE AND BOTTLE SHIELDS IN NUCLEAL! MEDICINE Description of Circumstances:

The Nuclear Regulatory Commission (NRC) is taking this opportunity to reinforce the importance of the use of radiation shields for syringes and bottles for nuclear medicine.

In many cases they are r.ot always being used by persons preparing and administering doses of radiophar-maceuticals. This is a potentially unsafe practice as these shields reduce the radiation dose to the fingers and hands of persons handling the syringes and bottles and can result in unnecessary and undesirably high total dose to the fingers over a period of time.

Calculations and studies show that failure to use the protective shields can result in a radiation dose rate to fingers of hospital staff personnel on the order of 100 mrads to one rad per minute, or a projected lifetime dose to the fingers in some cases of about 4,000 to 100,000 rads.

Notice to Medical Licensees:

Medical licensees are required to have and use these protective shields.

This requirement is imposed by either a specific condition of the NRC license or by procedures which are incorporated into the license.

As part of their routine audit program, NRC licensees authorized to use byproduct material pursuant to 10 CFR 35 should take the following actions:

Verify that protective shields are available and that nurses a.

and other medical personnel are using them, except in special circumstances, such as pediatric cases, when the use of syringe shields would compromise the patient's well-being.

b.

Inform the people involved in thi type of work of the potentially high and serious radiation doses that can be received by the hands and fingers if the protective shields are not used.

The information contained in this Circular should be brought to the attention of all personnel who prepare and administer licensed radio-pharmaceuticals to patients.

No written response to this Circular is required.

If you require ad-ditional information regarding this subject, please contact the Director of the appropriate NRC Regional Office.

O

)L' 7905020110