Form NRC418 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE 10 C R 71 For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.
1.(c) Package Identification No.
1.(d) Pages No. 1.(e) Total No. Pages 9006 2
USA /9006/B( )
1 2
- 2. PREAMBLE 2.(a)
This certificate is issued to satisfy Sections 173.393a 1 3.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amendef.
2.(b)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, ** Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."
2.(c) 1his certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agenaies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)
Frepared by (Name and address):
3.(b)
Title and identification of report or application:
Automation Industries, Inc.
Automation Industries, Inc. application P. O. Box 245 dated July 25, 1973, as supplemented.
Phoenixville, Pennsylvania 19460 3.(c)
Docket No.
71 OnnA
- 4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified
! :t::- 5 tc':e,
- 5. Description of Packaging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and
References:
(a) Packaging (1) Model No.:
500-SU (2) Description A radiographic source changer consisting of a welded 10 gage stainless steel box, approximately 5" wide x 6" high x 11" long. The source changer has a positive closure hinged flat plate cover and a depleted uranium shield.
Two titanium tubes are positioned in the center of the depleted uranium and house the source capsules and the source cable assemblies.
The two openings are closed by threaded caps. The gross weight is approximately 60 pounds.
(3) Drawings The packaging is constructed in accordance with Automation Industries, Inc. Drawings Nos. 500-SU and 500-50-1.
1788 258 80012202 0 9
Page 2 - Certificate No. 9006 - Revision No. 2 - Docket No. 71-9006 5.
(b) Contents (1) Type and form of material Iridium-192 as a sealed source which meets, the requirements of special form as defined in 571.4(o) of 10 CFR Part 71.
(2) Maximum quantity of material per package 300 curies 6.
The source shall be positioned within the Titanium tubing by a source cable assembly which meets the parameters shown in Automation Industries, Inc. Drawing No. SK-500-SU.
7.
The name plate shall be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining its legibility.
8.
The package authorized by this certificate is hereby approved for use under the general license provisions of Paragraph 71.12(b) of 10 CFR Part 71.
9.
Expiration date: January 31, 1985.
REFERENCES Automation Industries, Inc. application dated July 25, 1973.
Supplement dated:
November 28, 1973.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION fY Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:
'S11 1930 1789 259