Requests Comments on RCPB Safety Function Figure 5.3-2, Pressurizer Sys Fails to Prevent RCS Overpressure
ML19291C065
Person / Time
Issue date: 07/30/1979
From: Angelo J
Office of Nuclear Reactor Regulation
To: George H, Srinivasan M, Zwolinski J
Office of Nuclear Reactor Regulation
References
REF-GTECI-A-17, REF-GTECI-SY, TASK-A-17, TASK-OR NUDOCS 8001110349
Download: ML19291C065 (1)


Text

,E o.,

UNITED STATES C4I y

g NUOLEAR REGULATORY COMMISSION g '-

I

.E WASHINGTON, D. C. 20555 k

.+p JUL 3 01979 Generic Task No. A-17 NOTE T0:

J. Zwolinski D. Fischer H. George T. Scarbrough M. Srinivasan J. Murphy FROM:

J. Angelo

SUBJECT:

FAULT TREE (FIGURE 5.3-2) FOR THE REACTOR COOLANT PRESSURE BOUNDARY (RCPB) SAFETY FUNCTION Enclosed is Figure 5.3-2 for the reactor coolant pressure boundary safety function for your review.

Your conments and evaluation is requested by August 4,1979 so that all comments can be coordinated for the scheduled meeting with Sandia Laboratories in Albuquerque, NM on August 8-9, 1979.

The enclosed fault tree depicts the intermediate event " PRESSURIZER SYSTEM FAILS TO PREVENT RCS OVERPRESSURE" and, as such, completes the fault tree for RCPB for all operational occurrences from power operation (Mode 1) to hot shutdown (Mode 4).

The RCPB safety function series of fault trees is now complete ~and consists of Figure 5.3 and Figures 5.3-1 through 5.3-7, inclusive,

~

l J. Angelo Task Manager Task No. A-17

Enclosure:

Figure 5.3-2 cc:

S. H. Hanauer R. Budnitz M. Aycock V W. Vesely l/ 343 we M. Taylor F. Rowsome M. Chiramal J. Norberg L. Soffer L. Lois 8 0 011103+7}}