QQv\\biOb I
RS
=
r i
fia rch 15, 1985 On lY i
Docket No. 50-289 MEMORANDUM FOR:
Chairman palladino Ccamissioner Roberts Commissioner Asselstine Commissioner Bernthal Commissioner Zech FROM:
Hugh L. Thompson, Jr., Director Division of Licensina, NRR Sl!BJECT:
BOARD NOTIFICATION (EN-85-028)
RECENT DEVELOPMENTS RELATED TO TMI-1 STEAM GENEPATORS This Notification is being provided to the Commission in accordance with the revised Commission's notification policy of July 6,1984, to inform the Conriission on all issues on the cases befcre the Commission or issues which may involve substantial public, press, or Congressional interest.
The staff has issued its SEP on loose steam generator tube plugs in which it concluded that the GpU program to identify and correct defective pluos is adequate, and that there is reasonable assurance that the repaired plugs will maintain pressure boundary integrity and that operation with the missing plugs remaining in the reactor system will not result in a sionificant safety concern.
The licensee has submitted its evaluation of the cause of the defect indications found in the November 1984 eddy current tests (ECT).
Approximately 300 tubes were identified as having defects exceeding the present repair limit. The cause as determined by the licensee is " grain dropout" from previously existing islands of interaranular attact, making the damaged area more visible to ECT. The staff is reviewing this submittal, dated January 14, 1985 which is enclosed.
GPUN has also submitted recuests to revise the repair limit depth for limited arc length defects based on maintaining the licensed margin of safety using an alternate analysis approach and considering improved defect characteri7etion capability. The licensee proposes that this chance be made without a change in the Technical Specifications, in accordance with the current wording of the Technical Specifications. The two licensee submittels on this matter dated January 31 and March 1, 1985 are enclosed. A meeting was held with the licensee on February 19, 1984 to discuss both the technical and procedural aspects of this request, which is currently under staff review.
A copy of the meeting summary is enclosed.
%%W zg
1 Memo to Commissioners All interested parties have been provided copies of the meeting summary.
Other documents will be provided to the parties with this meniorandum.
'ggnk r: r:G Nf 03 1
Hugh L. Thompson, Jr., Director Division of Licensing, NRR
Enclosures:
As Stateds cc w/ enclosure:
Judge Sheldon J. Volfe, ASLB Judge Gustava A. Linenberger, Jr., ASLB Judge Ivan W. Smith, ASLB Judge Reginald L. Gotchy, ASLAB Judge Christine N. Kohl, ASLAB Judge Gary L. Edles, ASLAB Parties to Hearing OPE OGC ED0 SECY-2 ACRS-10
?
O AD{.P:
Mfhbm)pson n
OPP f(#.%, __._
Tt@!pd, SP C-
- DL DL HSilvM ;cf RStar _
J 7
GLdi as 3/ V84 3/(q/84 3
BN 3/pB4 3/j/84 f
CPU Nuclear Corporation 50-289, TMI-1 Pr. R.
- 1. Toole Jordan D. Cunningham, Esc.
O&M Director, TMI-1 Fox, Farr and Cunnincham GPU Nuclear Corporatinn 2320 Nor'.h 2nd Street Middletown, Pennsylvania 17057 Harrisb9ro, Pennsylvania 17110 Board of Directors Ps. Louise Bradford P.A.N.E.
TMIA P. O. Box 268 1011 Green Street Middletown, Pennsylvania 170E7 Harrisburg, Pennsylvania 17102 Docketing and Service Section Ms. Mar,iorie M. Aamodt U. S. Nuclear Regulatory Commission R. D. #5 Washington, D. C.
20555 Coatesville, Pennsylvania 19320 Chauncey Kepford Earl B. Hoffman Judith H. Johnsrud Dauphin County Commissioner Environmental Coalition on Nuclear Power Dauphin County Courthouse 433 Orlando Avenue Front and Parket Streets State College, Pennsylvania 16801 Harrisburg, Pennsylvania 17101 Judge Reginald L. Gotchy Ellyn R. Weiss Atomic Safety A Licensing Appeal Board Harmon, Weiss & Jordan U. S. Nuclear Pegulatory Commission 2001 S. Street Washington, DC 20555 Suite 430 Washington, DC 20009 Mr. Thomas E. Murley, Pegional Administrator Ivan W. Smith, Esq., Chairman U. S. N. R. C., Region I Atomic Safety and Licensino Board 631 Park Avenue U.S. Nuclear Regulatory Commission ring of Prussia, Pennsylvania 19a06 Washington, DC 20555 ANGRY /TMI PIRC Gary J. Edles, Chairman 1037 Maclay Street Atomic Safety & Licensing Appeal Harrisburg, Pennsylvania 17103 Poard U.S. Nuclear Regulatory Commission John Levin, Esq.
General Counsel Pennsylvania Public Utilities Federal Emergency Management #gency Commission AT1N:
Docket Clerk Box 3?65 1725 I Street, NW Harrisburg, Pennsylvania 17120 Washington, DC 20472 Parvin 1. Lewis Karin W. Carter, Esq.
6504 Bradford Terrace 505 Executive House Philedelphia, Pa'nsylvania 19149 P. O. Box ?357 Harrisburg, Pennsylvania 17120
GPU Nuclear Corporation Pr. Thomas M. Gerusky, Director Dr. James Lamb Bureau of Radiation Protection 313 Woodhaven Road Pennsylvania Department of Chapel Hill, North Carolina 27514 G. F. Trowbridge, Esq.
Dauphin County Office Emergency Shaw, Pittman, Potts & Trowbridge Preparedness 1800 M Street, N.W.
Court House, Room 7 Washington, DC 20036 Front A Market Streets Harrisburg, Pennsylvania 17101 Richard.l.
McGoey Christine N. Kohl, Esq.
Manacer, PWR Licensing Atomic Safety T Licensing Appeal GPU Nuclear Corporation Board 100 Interpace Parkway U.S. Nuclear Regulatory Connission Parsippany, New Jersey 07054' Washington, DC 70555 Ad Crable Mr. Robert B. Borsum Lancaster New Era Babcock & Wilcox 8 West King Street Nuclear Power Generation Division Lancaster, Pennsylvania 17602 Suite 220, 7910 Woodmont Avenue Bethesda, Maryland 20814 Dr. David Hetrick Mr. Gustave A. Linenberger, Jr.
Professor of Nuclear Energy Atomic Safety and Licensing Board University of Arizona U.S. Nuclear Regulatory Conmission Tucson, Arizona 85'21 Washington, DC 20555 Mr. David D. Maxwell, Chairman Mr. C. W. Smyth Board of Supervisors TMI-1 Licensing Manager Londonderry Township GPU Nuclear Corporation RFDf1 - Geyers Church Road P. O. Box 480 Middletown, Pennsylvania 17057 Middletown, Pennsylvania 17057 Regional Radiation Representative Governor's Office of State Planning EPA Region III and Development Curtis Building (Sixth Floor)
ATTN:
Coordinator, Pennsylvania 6th and Walnut Streets State Clearinghouse Philadelphia, Pennsylvania 19106 P. O. Box 1323 Harrisburg, Pennsylvania 17120 Mr. Richard Conte Sheldon J. Wolfe, Esq., Chairman Senior Resident Inspector (TMI-il Atomic Safety & Licensing Board U.S.N.R.C.
Washington, DC ?0555 P. O. Box 311 Middletown, Pennsylvania 17057 Jane Lee 183 Valley Road Ms. Jane Perkins Etters, Pennsylvania 17319 City Government Center 10 Porth Market Square Bruce Molholt Parrisburg, Pennsylvania 17101 Haverford College Haverford, Pennsylvania 10041
GPU Nuclear Corporation Norman Aamodt Michael McP. ride Esq.
R. D. #5, Box 428 LeBoeuf, Lamb, Leiby & McDae Coatesville, Pennsylvania 19370 Suite 1100 1333 New Hampshire Avenue, N.W.
Beverley Davis Washington, DC 20036 000 Gettysburg Pike Mechanicsburg, Pennsylvania 17055 Donald E. Hossler
- 50) Vine Street James B. Hurst Middletown, Pennsylvania 17057 617 Br'.arcliff Pcad Middletown, Pennsylvania 17057
.