} 'g -#pn *Ecoq'o, UNITED STATES

.n g j

NUCLEAR REGULATORY COMMISSION 2 c REGION V 8

1990 N. CALIFORNIA BOULEVARD o

e SUITE 202, WALNUT CREEK PLAZA 4,,,a WALNUT CREEK, CALIFORNIA 94596 December 5, 1980 x.qAy ENGINEERING CouPANY 1118 CHESS ORIVE FOSTER CITY CA 9440a NRC LIC. as Ou.00e16 0a Gentlemen:

The enclosed Circular 80-25 is sent for your information as a follow-on to the case history cocument tnat was recently sent to you.

Tha; document is provided to assist you in your raclograpner training program.

If you need additional information regaroing this subject please contact this office.

Sincerely,

,-( A f (.L _

c

1. H. Engelken Director

Enclosures:

.u, M v-1.

IE Circular ?!o. F0-25 2.

Recently Issued '.E Circulars I

o u,,

l.6 !

I.

d R.

u, C

(

f

s-d SSINS No: 6830 Accession No.-

8003220273 IEC 80-25 fI;f)

})

cn7 UNITED STATES TC EAR REGUL ATORY CC'"11SSICN NFICE OF INSPFCTIO ' AND Ei!FOPCE"ENT Y

I

..M HIFGT0"!, D. C.

20555 Decerter 5, 1980 IE Circular No. 00-25:

CASE HISTORIES OF RADICCRAPHY EVENTS Descrintion of Circumstances:

Durina and subsecuent to recional neetinos with industrial radicaraphers in 1977-70, discussions indicated that the review of case histories of radiorraphy incidents was a valuaDie trainino tool.

Subseouently, Apnendix A of 10 CFR Part 34 was arenced (flarch 3, 198() to include case histories as a required training subject.

You have recently been sent a cornilatinn of case histories concerninq overexposures, un"ecessary exposures and other unusual events tnat nave occurrea durino the conduct of radicaranny operations.

ihat docunent is intended to provide subject natorial for Item V, Aopencix A, 10 CFR Part 34.

T:otice to Padicaraphy Licensees Radiocrapny licensees are sequired by 10 CFR Part 34.31 (a)(1), which references,spendi; A, to include a renea of case nistories of radiography accidunts as part of the training progran for radiographers.

URC licensees authorized to use byproduct oaterial pursuant to 10 CFR Part 34 should include the cne history document in their radiographer trainina program as reouired subject ratter Additional ccpies can

_ cDtained f rom the NRC/GPO Sales Progran, USNRC, Washington, D.C. 20555, for $1.75 a copy.

For ease in ordering you should reference the document as I;UPEG/CR-001, Vol. 1.

No written response to this Circular is recuired.

If you need additional inforration with regard to this subject, please contact the appropriate recinnal office.

IEC 80-25 December 5,1980 PECENiLY ISSUED IE CIRCULARS Circular Cate of No.

Subject Issue Issued to 80-24 AECL Teletheraoy l! nit 12/2/30 All teletherapy P11 function licensees 80-23 Potential Defects in Beloit 10/31/30 All i:uclear power Power Systens Energency facilities having an Generators OL or a CP 80-22 Confirratioc of Fnoloyee 10/2/80 All holders of a cualifications power reactor OL or CP a rchi tect-enoineering companies and nuclear steam systnm suppliers 80-21 Regulation of Fefueling 9/10/C0 All holders of a Crews power reactor OL or CP 30-20 Channes in Safe-51ab Tank 8/21/80 All Part 50 and Part Dinensions 70 fuel facility licensees 80-19 Nonccmuiiance with 1/26/80 All nedical licensees License Requirenents for

."edical Licensees 80-18 10 CFR 50.59 Safety 8/22/30 All power reactor Evalua tions for Changos to facilities with an Raaicactive Waste Treatment OL or CP Systens 80-17 fuel Pin Damage Due to Water 7/23/30 All holders of PWR Jet fran Caffle Plate Corner OLs and PWR cps 80-16 Oporational Deficiencies In 6/27/80 All power reactor Rosonount Model 5100U Trip facilities with an Units And Podel 1152 Pressure OL or a CP Transmitters 80-15 Loss 01 Peactor Coolant Puno 6/20/80 All power reactor Cooling and Natural Circula-facilities with an tion Cooldown OL cr CP