ML19290G812

From kanterella
Jump to navigation Jump to search
Forwards IE Circular 80-25, Case Histories of Radiography Events. No Written Response Required
ML19290G812
Person / Time
Issue date: 12/05/1980
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
TECHNICAL WELDING LABORATORIES, INC.
References
NUDOCS 8012190320
Download: ML19290G812 (1)


Text

f2W.

r.u,,

[

o UNITED STATES

,(f k NUCLEAR REGULATCRY COMMISSION i

^y' s

iEG10N V 8

1930 fl. CALF FORNIA BOULEVARD 0,

SUITE 002, WALNUT CREEK PLAZA e,,*

WALNUT CR EEK, CALMORP!I A 94596 Cecember 5, 1980 TECHNICAL WELDING LA90RATORIES INC.

5727 NORTs0 ALE HOUSTON TX 77087 NRC LIC. 81 42-17119 01 8-Gentlemen:

The enclosed Circular 80-25 is sent for your information as a follow-on to the case history cocument tnat was recently sent to you.

That document is providea to assist you in your raclograpner training progi an.

If you neea acoitional inr'ormation regarcir.g this subject please contact this office.

S i r.ce rely,

,~mtL -

Engelken Director

Enclosures:

w-1.

IE Circular t'o. 80-25 2.

Recently Issued IE Circulars v

5

~

t$

[2,

(

e A

e

)

g c.

Ir 8C]2120 32o

SSINS No: 6830 Accession No.-

8003220273 IEC 80-25

"':ITED STATES "JC:S'R REGULATORY CC" MISSION CrrICE W INSPECTIC" AND ENFORCE"ENT f

[]

3 MEPI"3TO':, D. C.

20555 i

=S s eu Decenter 5, 1980 IE Circular No. 80-25:

CASE HISTORIES OF PADIOGRAPHY EVENTS Description of Circunstances:

Durina and subsecuent to recional neetinos with industria.1 radiooraphers in 1977-73, discussions indicated that the review or case histories of radionrachy incidents was a valuaDie trainina tool.

Subseauently, Appendix A of 10 CFR Part 34 was amended (Narcn 3,1980) to include case histories as a recuired training subject.

You have recently been sent a connilation of case nistories concerning overexposures, unnecessary exposuces and other unusuai events tnat nave occurred during the conouct of radienraony operatitis.

That document is intended to provide subject raterial for Iten V, Aopencix A, 10 CFR Part 34.

Notice to Padiogranny Licensees Radiograpny licensees are required by 10 CFR Part 34.31 (a)(1), which references Appendix n,

to include a revie.v of case histories of radiooraphy accident as part of the training program for radiograpners.

NRC licensees authorized to use bypredoct caterial pursuant to 10 CFR Part 34 should include the case history docunent in their radiographer trainino program as required subiect matter.

Additional copies can,,_ obtained f rom the NRC/GPO Sales Progran, USNRC, Washington, D.C. 20555, for $1.75 a cony.

For ease in ordering you should r'ference the docunent as NUP.EG/CR-Col, Vol.1.

No wrirNn rest:ense to this Circular is reauired.

If you need additional iriforration with regard to this subject, please contact the appropriate regional of fice.

IEC 80-25 December 5, 1980 RECENTLY ISSUED IE CIRCULARS Circular Late of No.

Subject Issue Issued to 30-24 AECL Teletherapy Unit 12/2/00 All teletherapy Malfunction licensees 80-23 Potential Defects in Eeloit 10/31/80 All Nuclear power Power Systens Energency facilities having an Generators OL or a CP 80-22 Confirration of Emolovee 10/2/30 All holders of a cualifications power reactor OL or CP architect-engineering conpanies and nuclear steam system suppliers 80-21 Regulation of Refueling 9/10/00 All holders of a Crews power reactor OL or CP S0-20 Channes in Safe-Slab Tank 8/21/80 All Part 50 and Part Dirensions 70 fuel facility licensees 80-19 Nonccmaliance aitn C/26/80 All redical licensees License Requirenents for "edical Licensees 80-18 10 CFR 50.59 Safety D/22/80 All power reactor Cvaluations for Char.ges to facilities with an Radioactive Waste Treatment OL or CP Systems 30-17 fuel Pin Damage Due to Mater 7/23/80 All holders of PWR Jet from Daffle Plate Corner OLs and PWR cps 80-16 Operational Deficiencies In 6/27/30 All power reactor Roserount Model 510DU Trip facilities with an Units Ana "odel 1152 Pressure Ot or a CP Transmitters E0-15 Loss of Reactor Coolant Pump 6/20/80 All power reactor Cooling and Natural Circula-facilities with an tion Cooldown OL or CP