Text
g 'pa arog
, -f[} ).c ;,}o, UNITED STATES
~ ',
(.-
j NUCLEAR REGULATORY COMMISSION REGION 11 3 eg[" s _; e8 101 MARIETTA ST.. N.W., SulTE 3100 o, -
8 ATLANTA, GEORGIA 30303
%, ' %./
o m
mu In Reply Refer To:
'3 RII:JPO M a di na 5 M A.v [, t w = 31 L A S w a siir. CuwPANY 400 atb 1 v i r.t bintti LtalaGTtW AY 40507 M t. LIC. a3 <10 - 1 19 ?f - V C '
Gentlemen:
The enclosed Circular 80-25 is sent for your information as a follow-on to the case history document that was recently sent to you.
That document is provided to assist you in your radiographer training program.
If you need additional information regarding this subject, please contact this office.
Sincerely;
- W'3 wV /
'N
.James 7. O'Reilly Director
Enclosures:
1.
IE Circular No. 80-25 2.
List of Recently Issued IE Circulars 801219U [2.h
SSINS No: 6830 Accession No.
8008220273 P's UNITED STATES
/N NUCLEAR RI.GULATORY COMMISSION
{-& ', (pg.{.
OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D. C.
20555 December 5, 1980 IE Circular No. 80-25:
CASE HISTORIES OF RADIOGRAPHY EVENTS Description of Circumstances:
During and subsequent to regional meetings with industrial radiographers in 1977-7s, discussions indicated that the review of case histories of radiography incidents was a valuable training tool.
Subsequently, Appendix A of 10 CFR Part 34 was amended (March 3, 1980) to include case histories as a required training subject.
You have recently been sent a compilation of case histories concerning overexposures, unnecessary exposures and other unusual events that have occurred during the conduct of radiography operations.
That document is intended to provide subject material for Item V, Appendix A, 10 CFR Part 34.
Notice to Radiography Licensees Radiography licensees are required by 10 CFR Part 34.31 (a)(1), which references Appendix A, to include a review of case histories of radiography accidents as part of the training program for radiographers.
NRC licensees authorized to use byproduct material pursuant to 10 CFR Part 34 should include the case history document in their radiographer training program es required subject matter.
Additional copies can be obtained from the NRC/GPO Sales Program, USNRC, Washington, D.C. 20555, for $1.75 a copy.
For ease in ordering you should reference the document as NUREG/BR-001, Vol.
1.
No written response to this Circular is required.
If you need additional information with regard to this subject, please contact the appropriate regional office.
IEC 80-25 December 5, 1980 RECENTLY ISSUED IE CIRCULARS Circular Date of No.
Subject Issue Issued to 80-25 Case Histories of 12/5/80 All radiography Radiography Events licensees 80-24 AECL Teletherapy Unit 12/2/80 All teletherapy Malfunction licensees 80-23 Potential Defects in Beloit 10/31/80 All Nuclear power Power Systems Emergency facilities having an Generators OL or a CP 80-22 Confirmation of Employee 10/2/80 All holders of a Qualifications power reactor OL or CP architect-engineering companies and nuclear steam system suppliers 80-21 Regulation of Refueling 9/10/80 All holders of a Crews power reactor OL or CP 80-20 Changes in Safe-Slab Tank 8/21/80 All Part 50 and Part Dimensions 70 fuel facility licensees 80-19 Noncompliance with 8/26/80 All medical licensees License Requirements for Medical Licensees 80-18 10 CFR 50.59 Safety 8/22/80 All power reactor Evaluations for Changes to facilities with an Radioactive Waste Treatment OL or CP Systems 80-17 Fuel Pin Damage Due to Water 7/23/80 All holders of PWR Jet from Baffle Plate Corner OLs and PWR cps 80-16 Operational Deficiencies In 6/27/80 All power reactor Rosemount Model 510DU Trip facilities with an Units And Model 1152 Pressure OL or a CP Transmitters 80-15 Loss of Reactor Coolant Pump 6/20/80 All power reactor Cooling and Natural Circula-facilities with an tion Cooldown OL or CP