ML19290G742

From kanterella
Jump to navigation Jump to search
Forwards IE Circular 80-25, Case Histories of Radiography Events. No Written Response Required
ML19290G742
Person / Time
Issue date: 12/05/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
MATERIALS TESTING LABORATORY, INC.
References
NUDOCS 8012190122
Download: ML19290G742 (1)


Text

.,

'r UNITED STATES NUCLEAR REGULATORY COMMISSION

~

3 E

REGION ll 0,,

[

101 MARIETTA ST., N.W., SUITE 310o f

ATLANTA, GEORGIA 303o3

,o DEC 5 1980 In Reply Refer To:

RII:JPO

,' i n.

MATERIALS TCSTING LABORATORY OF LAB 2706 WYOMING AVENUE NORFOLK VA 23502 NRC LIC. 8:

OLS-17151-01 1

Gentlemen:

The enclosed Circular 80-25 is sent for your information as a follow-on to the case history document that was recently sent to you. That document is provided to assist you in your radiographer training program.

If you need additional information regarding this subjecc, please contact this office.

Sincerely, JamesT O'Rei.lly */

Director

Enclosures:

1.

IE Circular No. 80-25 2.

List of Recently Issued IE Circulars 8012190 M 2.

SSINS No: 6830 Accession No.:

8008220273 UNITED STATES NUCLEAR REGULATORY COMMISSION r

OFFICE OF INSPECTION AhT, ENFORCEMENT WASHINGTON, D. C.

20555 December 5, 1980 IE Circular No. 80-25:

CASE HISTORIES OF RADIOGRAPHY EVENTS Description of Circumstances:

During and subsequent to regional meetings with industrial radiographers in 1977-78, discussions indicated that the review of case histories of radiography incidents sas a valuable training tocl.

Subsecuently, Appendix A of 10 CFR Part 34 was amended (March 3, 1980) to include case histories as a required training subject.

You have recently been sent a compilation of case histories concerning overexposures, unnecessary exposures and other unusual events that have occurred during the conduct of radiography operations.

That document is intended to provide subject material for Item V, Appendix A, 10 CFR Part 34.

Notice to Radiography Licensees Radiography licensees att required by 10 CFR Part 34.31 (a)(1), which references Appendix A, to include a review of case histories of radiography accidents as part of the training program for radiographers. NRC licensees authorized to use byproduct material pursuant to 10 CFR Part 34 should include the case history d::ument in their radiographer training program as required subject matter.

Additional copies can be obtained from the NRC/GPO Sales Program, USNRC, Washington, D.C. 20555, for $1.75 a copy.

For ease in ordering you should reference the document as NUREG/BR-001, Vol 1.

No written response to this Circular is required.

If you need additional information with regard to this subject, please contact the appropriate regional office.

IEC 80-25 December 5, 1980 RECENTLY ISSUED IE CIRCULARS Circular Date of No.

Subject Issue Issued to 80-25 Case Histories of 12/5/80 All radiography Radiography Events licensees 80-24 AECL Teletherapy Unit 12/2/80 All teletherapy Malfunction licensees 80-23 Potential Defects in Beloit 10/31/80 All Nuclear power Power Systems Emergency facilities having an Generators OL or a CP 80-22 Confirmation of Employee 10/2/80 All holders of a Qualifications power reactor OL or CP architect-engineering companies and nuclear steam system suppliers 80-21 Regulation of Refueling 9/10/80 All holders of a Crews power reactor OL or CP 80-20 Changes in Safe-Slab Tank 8/21/80 All Part 50 and Part Dimensions 70 fuel facility licensees 80-19 Noncompliance with 8/26/80 All medical licensees License Requirements for Medical Licensees 80-18 10 CFR 50.59 Safety 8/22/30 All power reactor Evaluations for Changes to facilities with an Radioactive Waste T reatment OL or CP Systems 80-17 Fuel Pin Damage Due to Water 7/23/80 All holders of PWR Jet from Baffle Plate Corner OLs and PWR cps 80-16 Operational Deficiencies In 6/27/80 All power reactor Rosemount Model 510DU Trip facilities with an Units And Model 1152 Pressure OL or a CP Transmitters 80-15 Loss of Reactor Coolant Pump f/20/80 All power reactor Cooling and Natural Circula-facilities with an tion Cooldown OL or CP