Ack Receipt of & Forwards Info Required for Review & Approval of Model Nupac 50
ML19290G705
Person / Time
Site: 07109145
Issue date: 12/03/1980
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Hansen L
NUCLEAR PACKAGING, INC.
References
NUDOCS 8012180405
Download: ML19290G705 (2)


Text

'

}p ' *

  • c q f,

UNITED STATES f,%

1' i NUCLEAR REGULATORY COMMISSION 5

(: c2 5

V. ASHNG TON, D. C. 205%

\\,,rk.E[e/

..s -

DEC 0 3 lE N

FCTC: RHO C

71-9145

,3 Nuclear Packaging, Inc.

d eg ATTN:

Mr. Larry J. Hansen

~

4 E15 South 28th Street Tacora, WA 98409 Gentlemen:

This refers to your application dated September 19, 1980, requesting approval of the Model No. NUPAC 50 packagings.

In connection with our review, we need the information identified in the encicsure to this letter.

Please advise us within thirty (30) days from the date of this letter when this information will be provided.

The additional informatien requested by this letter should be submitted in the form of revised pages.

If you have any questions regarding this matter, we would be pleased to meet with you and your staff.

Sincerely, Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety

Enclosure:

As stated 8 01218o j0 5 l

Nucit'- Pack 6ging, Inc.

Model no. NUPAC 50 Packagings DEC 03 GE-Encl to ltr dtd:

1.

Provide the sources of the mechanical properties of materials listed in Section 1.3.

2.

Clarify whether or not Option 1, Detail A, is only applicable for Cask Model 50-1.5L.

Revise the description of the 1/2 flat plate to show it is an annular ring plate.

Indicate on the drawing the size of this ring plate for other Cask Models.

3.

Describe and submit supporting documents for the design of the

" Ratchet Binder."

4.

Revise Drawing No. X-20-201D Sheets I and 2 to show materials of construction (shell and lid) and the welds between lifting or tie-down lugs to cask, 5.

Revise the thickness of the tie-down lug from 1-inch to 2-inches on Drawing No. X-20-201D, Sheet 2, to agree with the calculations in Section 1.4.4.

.