Responds to NRC Re Violations Noted in IE Insp Rept 50-364/80-33.Corrective Actions:Weld C-1 Radiographed W/Acceptable Results.Remaining Portions of Feedwater Welds Will Be Radiographed Per IE Bulletin 79-13
ML19290G699
Person / Time
Site: Farley 
Issue date: 12/02/1980
From: Mcdonald R
ALABAMA POWER CO.
To: Murphy C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19290G698 List:
References
IEB-79-13, NUDOCS 8012180384
Download: ML19290G699 (3)


Text

Alabama ower ompany 600 North 18th Street 4/

Post Office Box 2641 Birmingham, Alabama 35291 Telephone 205 250-1000 m

F. L. CLAYTON, JR.

Senior Vice President Alabama Power the Southern artrC Spiem December 2, 1980 J. M. Farley Nuclear Plant NRC Inspection of August 25-27, 1980 Mr. C. E. Murphy U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N.W.

Suite 3100 Atlanta, Georgia 30303

Dear Mr. Murphy:

Re: RII: BRC 50-364/20-33 This letter is to explain the corrective steps taken as a result of the item of noncompliance brought to our attention in your letter of Sep-tember 18, 1980 and your letter of November 20, 1980 requesting further explanation.

Item 1.a of IE Bulletin 79-13 required radiographic examination of nozzle to reducer welds in the feedwater lines with the area of inspection to include the weld and two base material thicknesses on either side of the weld.

Evaluation of the radiographs was to be in accordance with ASME Section III, Subsection NC, Article NC-5000 of the 1977 edition to the 2T penetrameter sensitivity level, in lieu of Table NC-5111-1.

In complying with this requirement Weld C-1 of Loop C was radiographed and evaluated.

This radiograph included adjacent pipe and nozzle areas within a distance equal to at least two wall thicknesses and was evaluated in accordance with ASME Section III, Subsection NC, Article NC-5000 and FNP-0-GMP-51.

Subse-quent review of this radiograph during the NRC inspection resulted in de-ficiency 50-364/80-33-01 because a discontinuity image on the film was 0.3 greater than the density tolerances allowed by FNP-0-GMP-51.

Alabama Power Company's response concerning the discontinuity image is explained in my letter to you dated October 15, 1980. At the time of the inspection a second radiograph was made of Weld C-1 and the density in the discontinuity area was within tolerance.

In your inspection report you stated the follow-ing:

" Based on the fact that the density did not meet procedure requirements in only one view in one small area and the area could be examined for the purpose of the bulletin, this item has minimal safety significance and, therefore, is a deficiency". As stated in my letter of October 15, 1980, QW E 012180 /

J

Mr. C. E. Murphy December 3, 1980 Page Two we do not normally take density readingc directly on a discontinuity image but take readings within the general weld area.

Based on your letter of November 20, 1980, the NRC's interpretation of the intent of IE Bulletin 79-13 is as follows:

"The area of interest shall include the weld and two base material thicknesses on either side of the weld.

In addition to code requirements for normal weld radiography, film density tolerances allowable by the code shall apply throughout the entire area of interest including discontinuity images."

In response to your requests, we submit the following:

(1)

Corrective steps which have been taken by. you and the results achieved.

Response

(a) Weld C-1 was radiographed during the inspection and the second radiograph had acceptable density readings.

The second radiograph will be retained as the official record of compliance with IE Bulletin 79-13.

(b) The additional radiographs taken subsequent to hot functional testing will be retained for information purposes only. During the first refueling on Unit 2, the remaining portions of the feedwater welds will be radio-graphed to meet the requirements of IE Bulletin 79-13.

(2)

Corrective steps which will be taken to avoid further non-compliance.

Response

IE Bulletins and other similar documents will be carefully reviewed to identify requirements which go beyond normal NDE methods and evaluations. Testing personnel will be properly instructed in meeting any special requirements.

In particular the pipe weld radiographs to be made and evaluated during the first refueling to comply with the remaining portion of IE Bulletin 79-13 will follow special instructions to satisfy the intent of the IE Bulletin.

(3) The date when full compliance will be achieved.

Response

Full compliance will be achieved as of 12-2-80.

Mr. C. E. Murphy December 3, 1980 Page Three The information contained in this letter is not considered to be of a proprietary nature.

Sincerely yours,

,, op (

1 i

dd /$ /h(vv..'f A

F. L. Clayton, Jr.

FLCJr/JGS:nac

.